Si12-619A
2.4
Removal of the
Procedure
Step
Remove the fan motor
lead wire connector.
Remove the propeller
1
fan by removing the
washer-fitted nut.
Remove the fan motor.
2
Remove the screw of
the fan motor mount.
Disconnect the lead
3
wire by releasing the 2
clamps fixing the wire.
Remove 4 screws of
the fan motor.
Removal Procedure
Fan Motor
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Outdoor Unit – E Series (68 / 71 / 75 Class), D Series
For reassembling, align
mark of propeller fan with
D-cut section of motor shaft.
Mount the propeller fan while
positioning
top.
When reassembling, fix the
lead wire to avoid contact
with the propeller fan.
Points
mark to the
311