Air Filter - Daikin D-Series Service Manual

Super multi nx d/e series
Hide thumbs Also See for D-Series:
Table of Contents

Advertisement

Instruction
Filters
1. Open the front panel.
2. Pull out the air filters.
• Push a little upwards the tab at the center of each air
filter, then pull it down.
3. Take off the Titanium Apatite Photo-
catalytic Air-Purifying Filter.
• Hold the recessed parts of the frame and unhook
the four claws.
4. Clean or replace each filter.
See below.
5. Set the air filter, Titanium Apatite
Photocatalytic Air-Purifying Filter as
they were and close the front panel.
• Insert claws of the filters into slots of the front panel.
Close the front panel slowly and push the panel at the
3 points. (1 on each sides and 1 in the middle.)

Air Filter

1. Wash the air filters with water or clean them with
vacuum cleaner.
• If the dust does not come off easily, wash them with neutral detergent
thinned with lukewarm water, then dry them up in the shade.
• It is recommended to clean the air filters every two weeks.
Titanium Apatite Photocatalytic
Air-Purifying Filter.
The Titanium Apatite Photocatalytic Air-Purifying Filter can be renewed
by washing it with water once every 6 months. We recommend replacing
it once every 3 years.
[ Maintenance ]
1. Remove dust with a vacuum cleaner and wash lightly with water.
2. If it is very dirty, soak it for 10 to 15 minutes in water mixed with a neutral cleaning agent.
3. Do not remove filter from frame when washing with water.
4. After washing, shake off remaining water and dry in the shade.
5. Since the material is made out of paper, do not wring out the filter when removing water from it.
[ Replacement ]
1. Remove the tabs on the filter frame and replace with a new filter.
• Dispose of the old filter as flammable waste.
170
Titanium Apatite
Photocatalytic
Air-Purifying Filter
Filter frame
Tab
Push
Si12-619A
Air filter
Tab
Operation Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents