Si011356EA Table of Contents 1. Outer Panels ...................2 2. Outdoor Fan / Fan Motor.................4 3. Electrical Components ................6 4. Sound Blankets ..................10 5. Capillary Tube ..................11 6. Compressor ASSY ................12 Note: The illustrations may be slightly different depending on the model. Removal Procedure...
Outer Panels Si011356EA 1. Outer Panels Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the screw and remove the stop valve cover. Stop valve cover (R16329) The stop valve cover is Shield plate...
Page 5
Si011356EA Outer Panels Step Procedure Points Lift up the left side and unfasten the hooks. (R20743) Release the right side hooks and remove the front panel. (R20744) Press the 2 projections Discharge grille from the rear side and rotate the discharge grille to remove it.
Outdoor Fan / Fan Motor Si011356EA 2. Outdoor Fan / Fan Motor Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the nut of the Nut size: M6 outdoor fan.
Page 7
Si011356EA Outdoor Fan / Fan Motor Step Procedure Points Remove the fan motor When reassembling, fit the fixing frame. lower hooks into the bottom frame. (R10460) (R19245) Remove the 3 screws Screw size: M4 × 16 and remove the fan Fan motor motor.
Electrical Components Si011356EA 3. Electrical Components Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the 7 screws on the terminal board and disconnect the connecting wire and the power supply wire.
Page 9
Si011356EA Electrical Components Step Procedure Points Unfasten the upper When reassembling, make hook. sure to fit the hook. Right side panel (R10467) Unfasten the hook and When reassembling, make remove the right side sure to fit the hook. panel. Hook (R19329) Remove the screw of the terminal board...
Page 10
Electrical Components Si011356EA Step Procedure Points Detach the fixing plate. Fixing plate (R19247) Remove the screw of Earth / the earth / ground wire. ground wire (R19248) Parts layout (R19253) Removal Procedure...
Page 11
Si011356EA Electrical Components Step Procedure Points Pull out the terminals from the magnetic to X1M (1) to X1M (3) contactor (K1M). : red (fuse) : white Remove the 2 screws and remove the magnetic contactor (K1M). to X1M (1) : red to compressor to X1M (2) (C terminal)
Sound Blankets Si011356EA 4. Sound Blankets Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the sound Since the piping ports on the blanket (top). sound blanket are torn easily, remove the sound Untie the 2 strings and blanket carefully.
Si011356EA Capillary Tube 5. Capillary Tube Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Be careful not to get yourself burnt with the pipes and other parts that are heated by the gas brazing machine.
Compressor ASSY Si011356EA 6. Compressor ASSY Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Be careful not to get yourself burnt with the pipes and other parts that are heated by the gas brazing machine.
Page 15
Si011356EA Compressor ASSY Step Procedure Points Remove the terminal cover. (R20749) Disconnect the Compressor lead wire compressor lead wires. For R-410A models R (V) S (W) C (U) (R15375) For R-32 models R ( V ) C ( U ) S ( W ) (R10484) ( R20742 )
Page 16
Compressor ASSY Si011356EA Step Procedure Points Heat up the brazed part Discharge side pipe of the discharge side pipe and disconnect it. Heat up the brazed part of the suction side pipe and disconnect it. Suction side pipe (R20750) Lift the compressor ASSY up and remove it.
Page 17
Revision History Month / Year Version Revised contents 08 / 2013 Si011356E First edition 09 / 2014 Si011356EA Model addition: ARM09MV2S, RM09NV2S, RM25JV14, RM25KV1V...
Page 18
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.
Need help?
Do you have a question about the ARM09MV2S and is the answer not in the manual?