Download Print this page

Advertisement

Quick Links

REMOVAL
PROCEDURE
S E R V I C E
3.5 kW Class
13000 Btu/h Class
Outdoor Unit
Non-Inverter
Pair Type
Si011184
M A N U A L

Advertisement

loading

Summary of Contents for Daikin R13LV2S

  • Page 1 Si011184 REMOVAL PROCEDURE S E R V I C E M A N U A L 3.5 kW Class 13000 Btu/h Class Outdoor Unit Non-Inverter Pair Type...
  • Page 2 Service Manual Removal Procedure Outdoor Unit Applicable Models Cooling Only R13LV2S AR13KV2S R35HV1 R35HV14 R35JV1V R35MV16...
  • Page 3: Table Of Contents

    Si011184 Table of Contents 1. Removal of Outer Panels / Fan Motor (Pattern 1)........2 2. Removal of Outer Panels / Fan Motor (Pattern 2).........10 3. Removal of Electrical Component ASSY (Pattern 1) ......18 4. Removal of Electrical Component ASSY (Pattern 2) ......19 5.
  • Page 4: Removal Of Outer Panels / Fan Motor (Pattern 1)

    Removal of Outer Panels / Fan Motor (Pattern 1) Si011184 1. Removal of Outer Panels / Fan Motor (Pattern 1) Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points...
  • Page 5 Si011184 Removal of Outer Panels / Fan Motor (Pattern 1) Step Procedure Points Remove the 3 screws and remove the top Top panel panel. (R16334) Remove the 4 screws and remove the discharge grille. (R16335) The discharge grille has 4 hooks.
  • Page 6 Removal of Outer Panels / Fan Motor (Pattern 1) Si011184 Step Procedure Points Remove the 8 screws of the front panel. (R16337) Front panel Unfasten the hooks. The front panel has 4 hooks. Pull and remove the front panel. Hook (R16338) Removal Procedure...
  • Page 7 Si011184 Removal of Outer Panels / Fan Motor (Pattern 1) Step Procedure Points 3. Remove the fan motor. Nut size: M6 Remove the nut of the outdoor fan. 10 mm (R17447) Outdoor fan (R15230) Remove the outdoor Align the mark of the fan.
  • Page 8 Removal of Outer Panels / Fan Motor (Pattern 1) Si011184 Step Procedure Points Remove the screw and Put the fan motor lead wire remove the fan motor through the back of the fan fixing frame. motor when reassembling so as not to be entangled with the outdoor fan.
  • Page 9 Si011184 Removal of Outer Panels / Fan Motor (Pattern 1) Step Procedure Points Release the fan motor lead wire from the hooks. (R15234) Remove the 4 screws and remove the fan motor. motor (R15235) Removal Procedure...
  • Page 10 Removal of Outer Panels / Fan Motor (Pattern 1) Si011184 Step Procedure Points 4. Remove the right side panel. Remove the 7 screws on the terminal board and disconnect the connecting wire and the power supply wire. Remove the screw and remove the wire clamp.
  • Page 11 Si011184 Removal of Outer Panels / Fan Motor (Pattern 1) Step Procedure Points Remove the 4 screws on the right side. Right side panel (R15238) Remove the screw near the connection port. (R15239) Unfasten the hook of When reassembling, make the right side panel.
  • Page 12: Removal Of Outer Panels / Fan Motor (Pattern 2)

    Removal of Outer Panels / Fan Motor (Pattern 2) Si011184 2. Removal of Outer Panels / Fan Motor (Pattern 2) Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points...
  • Page 13 Si011184 Removal of Outer Panels / Fan Motor (Pattern 2) Step Procedure Points Remove the 3 screws and remove the top Top panel panel. (R16334) Remove the 4 screws and remove the discharge grille. (R16335) The discharge grille has 4 hooks.
  • Page 14 Removal of Outer Panels / Fan Motor (Pattern 2) Si011184 Step Procedure Points Remove the 8 screws of the front panel. (R16337) Front panel Unfasten the hooks. The front panel has 4 hooks. Pull and remove the front panel. Hook (R16338) Removal Procedure...
  • Page 15 Si011184 Removal of Outer Panels / Fan Motor (Pattern 2) Step Procedure Points 3. Remove the fan motor. Nut size: M6 Remove the nut of the outdoor fan. 10 mm (R12236) Outdoor fan (R15230) Remove the outdoor Align the mark of the fan.
  • Page 16 Removal of Outer Panels / Fan Motor (Pattern 2) Si011184 Step Procedure Points Remove the screw and Put the fan motor lead wire remove the fan motor through the back of the fan fixing frame. motor when reassembling so as not to be entangled with the outdoor fan.
  • Page 17 Si011184 Removal of Outer Panels / Fan Motor (Pattern 2) Step Procedure Points Release the fan motor lead wire from the hooks. (R15234) Remove the 4 screws and remove the fan motor. motor (R15235) Removal Procedure...
  • Page 18 Removal of Outer Panels / Fan Motor (Pattern 2) Si011184 Step Procedure Points 4. Remove the right side panel. Remove the 7 screws on the terminal board and disconnect the connecting wire and the power supply wire. Remove the screw and remove the wire clamp.
  • Page 19 Si011184 Removal of Outer Panels / Fan Motor (Pattern 2) Step Procedure Points Remove the 4 screws on the right side. Right side panel (R15238) Remove the screw near the connection port. (R15239) Unfasten the hook of When reassembling, make the right side panel.
  • Page 20: Removal Of Electrical Component Assy (Pattern 1)

    Removal of Electrical Component ASSY (Pattern 1) Si011184 3. Removal of Electrical Component ASSY (Pattern 1) Procedure Warning Be sure to for wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Pull out the terminal to compressor (blue) from K1M (1).
  • Page 21: Removal Of Electrical Component Assy (Pattern 2)

    Si011184 Removal of Electrical Component ASSY (Pattern 2) 4. Removal of Electrical Component ASSY (Pattern 2) Procedure Warning Be sure to for wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Pull out the terminal (blue) from K1M (1).
  • Page 22: Removal Of Sound Blankets

    Removal of Sound Blankets Si011184 5. Removal of Sound Blankets Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the sound Preparation blanket (top). Remove the outer panels Sound according to the “Removal of Untie the 2 strings and...
  • Page 23: Removal Of Capillary Tube (Pattern 1)

    Si011184 Removal of Capillary Tube (Pattern 1) 6. Removal of Capillary Tube (Pattern 1) Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Before working, make sure that the refrigerant Warning gas is empty in the circuit.
  • Page 24: Removal Of Capillary Tube (Pattern 2)

    Removal of Capillary Tube (Pattern 2) Si011184 7. Removal of Capillary Tube (Pattern 2) Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Before working, make sure that the refrigerant Warning gas is empty in the circuit.
  • Page 25: Removal Of Compressor Assy

    Si011184 Removal of Compressor ASSY 8. Removal of Compressor ASSY Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the nut and remove the terminal cover.
  • Page 26 Removal of Compressor ASSY Si011184 Step Procedure Points Before working, make sure that the refrigerant Warning gas is empty in the circuit. Be careful not to get yourself Be sure to apply nitrogen burnt with the pipes and other Discharge side replacement when parts that are heated by the...
  • Page 27 Revision History Month / Year Version Revised contents 08/2012 Si011184 First edition...
  • Page 28 Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.

This manual is also suitable for:

Ar13kv2sR35hv1R35hv14R35jv1vR35mv16