CAUTION
Static sensitive components. A static discharge while handling
electronic circuit boards can cause damage to the components.
Discharge any static electrical charge by touching the bare metal
inside the main control panel before performing any service work.
Never unplug any cables, circuit board terminal blocks, relay
modules, or power plugs while power is applied to the panel.
Field Wiring Remote Mounted Temperature
Sensor
The low voltage field wiring connections have all been centrally located
within the unit ventilator and are easily accessible.
To simplify field connections, multi-pin plugs are factory provided and
pre-wired with short wire whips (see figure 57). Each of the wires in
these wire whips is capped and should remain capped if not used. The
unit mounted temperature sensor is provided with a quick disconnect
plug (white) with wires numbered 101 and 102, and must be separated
so that the unit mounted sensor is disconnected from the UVC. This
disables the unit mounted sensor (see figure 58). See Figures 59 and 60
for wiring the remote mounted temperature sensor to the unit control
wiring.
Figure 57: Wire whips with Caps for Field Wiring Remote
Mounted Temperature Sensor
Wire Wips for Field Wiring with Caps (see the wiring diagram
provided on the unit ventilator right front access panel)
NOTICE
All low voltage field wiring connections must be run in shielded
cable with the shield drain wires connected as shown in the
field wiring diagrams.
Figure 58: Quick Disconnect Plug, Wires 101 & 102 for
Unit Mounted Temperature Sensor
Two pin plug for unit-mounted sensor
IM 1083
Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ
Figure 59: Wall-Mounted Temperature Sensor Wiring for
Basic Wall Sensor
Unit Ventilator
P 1
Wire
C o n n e c t o r
C a p s
896
G N D
AI-2
GRN
B L K
C o m m
W H T
AI-1
LED
R E D
Figure 60: Wall Mounted Temperature Sensor Wiring for
Expanded Wall Sensor
BLK
Installing the Remote Mounted Temperature Sensor
NOTICE
The unit comes with a unit mounted sensor and does not require
a remote wall mounted sensor.
This describes the installation of the following three wall mounted
sensor models:
P/N 111048101 – Basic
P/N 111048103 – Expanded ± 3
Use the installation instructions included with the Remote wall
sensor.
Parts Included - All Models
pre-assembled sensor that includes:
- large (50.8 x 101.6 mm [2 x 4 in.]) mounting base (1)
- terminal block (1)
- 1.5 mm (1/16 in.) cover screw (1)
- end caps (2)
alternate small (80 x 80 mm [3.15 x 3.15 in.]) mounting
base (1) with attached terminal block (1)
cover slider insert with printed logo for Daikin (1)
No. 6-32 x 1 in. flat-head screw (2)
No. 8 x 1.25 in. panhead tapping screw (2)
hollow plastic wall anchor (2)
Parts Included - 111048103 Only
alternate serrated setpoint dial (attached)
smooth setpoint dial (separate)
Special Tools Needed
.5 mm (1/16 in.) Allen wrench
7 mm (1/4 in.) flat-blade screwdriver
hole saw with 35 mm (1-3/8 in.) blade (for surface mounting only)
drill with 8 mm (5/16 in.) drill bit (for surface mounting only)
W a l l S e n s o r
( o p t i o n )
1
S h i e l d
5
6
S e t p t . A d j .
4
C o m m
3
S e n s o r
2
LED
F a c t o r y W i r i n g
F i e l d W i r i n g ( b y O t h e r s )
E x t e r n a l D e v i c e ( b y O t h e r s )
F setting
o
Page 33 of 42