5. Power down the failed disk array.
Press the power button once on each power and cooling unit to turn the switch off
(
).
FIGURE 9-1
Power Switch Location
FIGURE 9-1
All arrays power down automatically when any one array in the partner group is
powered down.
6. Record the Sun StorEdge T3 and T3+ array system serial number and MAC
address.
Locate the pull-out tab at the left side of the array next to the first disk drive as
shown in
FIGURE 9-2
control (MAC) address. The serial number is located on the top left portion of the
pull-out tab and begins with the part number 595-xxxx. Record this information to
transcribe it onto the new chassis.
Pull-out tab
Serial Number and MAC Address on Pull-out Tab
FIGURE 9-2
Power switches
. This tab contains the array serial number and media access
Chapter 9 Chassis/Backplane Assembly
9-3