14. TYPICALLY FOR FACTORY BUILT ZC FIREPLACES, REFER TO PAGE 7.
Use Mendota Co-Axial Vent Kit -- # AA-11-00378
4" exhaust flex pipe extends full length of chimney - from vent boot adapter to vent cap. 6" inlet flex pipe
extends from vent boot adapter to existing chimney, above damper area (approx. 4 - 5 ft.). Tightly secure flex
vents with clamps provided. Seal vent cap/flashing to top of chimney with weatherproof sealer. Seal area
between 6" flex pipe and chimney, at damper area, with unfaced fiberglass insulation.
NOTE: In Canada, it is required that the 6" air inlet flex pipe extend up to the vent cap.
15.
TYPICALLY FOR MASONRY FIREPLACES, REFER TO PAGE 7.
Use Mendota Co-Linear Vent Kit -- # AA-11-00377
4" exhaust flex pipe extends full length of chimney - from vent boot adapter to vent cap. 4" inlet flex pipe
extends from vent boot adapter to existing chimney, above damper area (aprox.4-5 ft.). Tightly secure 4" flex
pipes using clamps provided. Seal vent cap/flashing to top of chimney with weatherproof sealer. Seal area
between 4" flex pipes and existing chimney, at damper area, with unfaced fiberglass insulation.
NOTE: In Canada, it is required that the 4" air inlet flex pipe extend up to the vent cap.
16.
You are now ready to install the Mendota Gas Insert.
A. Lift Insert vertically from carton/pallet.
17.
Remove 5/16" nut and locking u-clamp from vent boot adapter (See Pg. 13
18.
You are now ready to hook up the Insert to gas supply. Be sure gas plumbing instructions [Pg. 16 & 17] and all
state and local codes have been carefully followed. Be sure all items on Installation Check-Off List [Pg. 18]
have been completed.
NOTE: AGA APPROVED FLEX LINES ARE APPROVED FOR USE WITH MENDOTA INSERTS.
FIGURE 6
Glass Door Removal