SVFT-PRS Pressurized Dome Housing
Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet
your requirements or that the operation will be entirely error free or perform precisely as
described in the documentation. This system has not been designed to be used in life-critical
situations and must not be used for this purpose.
Copyright © 2008 Vicon Industries Inc. All rights reserved.
Product specifications subject to change without notice.
Vicon and its logo are registered trademarks of Vicon Industries Inc.
SurveyorVFT and Kollector are trademarks and ViconNet a registered trademark of Vicon Industries Inc.
ExView is a trademark of Sony Corporation.
VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788
TEL: 631-952-CCTV (2288) FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116
24-Hour Technical Support: 800-34-VICON (800-348-4266)
UK: +44(0) 1489-566300 WEB: www.vicon-cctv.com
Vicon Part No. 8009-8163-17-00
Section 3 Rev 1208

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SVFT-PRS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vicon SVFT-PRS

  • Page 1 XX163-17-00 SVFT-PRS Pressurized Dome Housing Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be entirely error free or perform precisely as described in the documentation. This system has not been designed to be used in life-critical situations and must not be used for this purpose.
  • Page 3 The product shows a significant change in performance. 6. Attachments - Use only UL Listed Vicon recommended attachments to prevent unit damage and personal injury. 20. Replacement Parts - Use only Vicon specified replacement 7.
  • Page 5: Fcc Notice

    Warning: Power must be removed from this unit before removing circuit modules or ribbon cables. Caution: This unit contains circuit cards with integrated circuit devices that can be damaged by static discharge. Take all necessary precautions to prevent static discharge. FCC Notice • iii XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 7: Table Of Contents

    Pressurizing the Housing Assembly....................... 18 Configuring the ViconNet (IP/LAN) Version....................20 ViconNet (IP/LAN) Version Operation ......................27 UNINSTALLING .........................27 OPERATION........................28 MAINTENANCE........................29 SHIPPING INSTRUCTIONS ....................30 CABLE RECOMMENDATIONS ..................31 TECHNICAL INFORMATION .....................34 VICON STANDARD EQUIPMENT WARRANTY..............39 Contents • v XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 8: Quick Installation

    Quick Installation vi • Quick Installation XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 9: Introduction

    Shipping Information section of this manual. Accessory Kit There is one (1) kit included with all configurations of the SVFT-PRS. It provides the necessary hardware to assist in assembling and wiring the SVFT-PRS. These screws and washers are spares for the lower dome.
  • Page 10 Table 2 Models, Product Codes and Descriptions Power Table (Includes the Housing and SurveyorVFT) Power Current Rating Model Number Coax, UTP, Fiber ViconNet Coax, UTP, Fiber ViconNet SVFT-PRS22E/C SVFT-PRS23/C SVFT-PRS35/C 2 • Introduction XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 11: Pressurized Housing Components

    Refer to the Maintenance Section of this manual for instructions on handling and care of this lower dome. Introduction • 3 XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 12: Installation

    Use the applicable sub-section to install the correct connector type included. Wall Mount Method Use this method to install, wire and configure a unit with a Vicon wall mount. Refer to Figure 2. Installing the Wall Mount 1.
  • Page 13: Installing The 23-Pin Connector Assembly

    Note: The wire color code may not match Figure 3. Verify each wire is labeled with a function. DO NOT remove the labels. Use the wire labels for absolute reference. Installation • 5 XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 14: Wiring And Assembling The 23-Pin Connector

    Note: The wire color code may not match Figure 3. Verify each wire is labeled with a function. DO NOT remove the labels. Use the wire labels for absolute reference. 6 • Installation XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 15: Housing Connections

    All the necessary connections are provided at the top of the housing, including the 23-pin connector and connectors for fiber video transmission and ViconNet (IP) video/data transmission. Refer to the figure below. Installation • 7 XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 16: Preparing The Camera Drive

    The Vicon SurveyorVFT is designed to store PTZ preset locations on the internal memory. Certain manufacturers’ controllers are designed to store PTZ preset locations in the controller. Therefore preset functionality in the Vicon dome will not work correctly with these types of controllers.
  • Page 17 1 - ON (NTSC), 2 - OFF (Serial), 3 - OFF (DUPLEX), 4 - OFF (RS-422), 5 through 8 - OFF (Vicon VPS) 20. Attach the housing’s safety clip to the camera drive’s tab. Tilt the camera drive down and orient the two (2) slots on the housing with the two (2) tabs on the drive and raise it until two distinct clicks are heard.
  • Page 18: Pressurizing The Housing Assembly

    Note: The pressurized function has not been evaluated by UL. Warning: Do not use any gas type other than dry Nitrogen. The use of Shop Air can introduce moisture into the housing assembly that can damage it over time. 10 • Installation XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 19 Figure 5 Pressurizing the Housing Installation • 11 XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 20: Pipe Mount Method

    Orient the service cover to a convenient position. 5. Tighten the two set screws on the neck of the mount using a hex key if additional security is desired. 12 • Installation XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 21: Installing The 23-Pin Connector Assembly

    On ViconNet units, A, C, D, P, T, L, M, J, K. X, and U are not used. Note: The wire color code may not match Figure 7. Use the wire labels for absolute reference. Installation • 13 XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 22: Wiring And Assembling The 23-Pin Connector

    Note: Use the provided large crimp connector for the Ground connection in the Control (RS-422/485) cable. Note: The wire color code may not match Figure 3. Use the wire labels for absolute reference. 14 • Installation XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 23: Housing Connections

    Housing Connections All the necessary connections are provided at the top of the housing, including the 23-pin connector and additional connectors for fiber and ViconNet (LAN). Refer to the figure below. Installation • 15 XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 24: Preparing The Camera Drive

    The Vicon SurveyorVFT is designed to store PTZ preset locations on the internal memory. Certain manufacturers’ controllers are designed to store PTZ preset locations in the controller. Therefore preset functionality in the Vicon dome will not work correctly with these types of controllers.
  • Page 25 1 - ON (NTSC), 2 - OFF (Serial), 3 - OFF (DUPLEX), 4 - OFF (RS-422), 5 through 8 - OFF (Vicon VPS) 20. Attach the housing’s safety clip to the camera drive’s tab. Tilt the camera drive down and orient the two (2) slots on the housing with the two (2) tabs on the drive and raise it until two distinct clicks are heard.
  • Page 26: Pressurizing The Housing Assembly

    Note: The pressurized function has not been evaluated by UL. Warning: Do not use any gas type other than dry Nitrogen. The use of Shop Air can introduce moisture into the housing assembly that can damage it over time. 18 • Installation XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 27 Figure 9 Pressurizing the Housing Installation • 19 XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 28: Configuring The Viconnet (Ip/Lan) Version

    Elite Recorders and ViconNet Workstations can be used for live viewing and recording of network-streamed video. A network can be as simple as a single SVFT-PRS connected to a ViconNet Workstation or can be complex with the addition of several networks interconnected via WAN.
  • Page 29 The password will be saved on this unit. Note: The unit password is supplied on the sticker with the MAC address in the camera package. Installation • 21 XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 30 Note: In order for the DHCP option to work properly, verify that the server does not expire the IP address licensed to the camera. (Camera should always receive the same IP address from the DHCP server.) Unit 22 • Installation XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 31 The Install TAB allows the user to install/upgrade newer versions. Choose the correct version and click Install to send to the selected unit. Install Info Tab The Info TAB displays the selected IP product general information/ Info Installation • 23 XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 32 Default setting is 1500. This setting also allows the VOX mechanism to be deactivated, having audio ON all the time. VOX Off Threshold – Defines the audio level at which the input shuts OFF. Default setting is 1200. 24 • Installation XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 33 (Note: Screen below is only a sample screen.) The word ViconNet remains on the screen until a PTZ action is taken. Note: The camera drive always returns to the pan and tilt coordinates it was initially powered-up with unless autohome on power-up was set. Opening Screen Installation • 25 XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 34 An Authorization screen is used to establish authority levels, by user group. Functions such as PTZ and video view, record and playback can be set for authority level. • A priority screen is used to establish video quality and FPS levels. 26 • Installation XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 35: Viconnet (Ip/Lan) Version Operation

    CD included. Uninstalling If it becomes necessary to uninstall to SVFT-PRS, follow the steps below. WARNING: Before starting to uninstall the unit, be sure to release all the pressure through the fill valve on the side of the unit.
  • Page 36: Operation

    Operation When power is applied to the camera, the SVFT-PRS will boot up through a diagnostic routine and view the currently selected scene. Refer to the latest version of the SurveyorVFT Programming Manual XX134-40 for details on setup and operation.
  • Page 37: Maintenance

    Maintenance The SVFT-PRS Camera Dome requires no scheduled maintenance except for the occasional cleaning of the lower dome. Care and Cleaning of Clear Polycarbonate Domes 1. Always handle the lower dome by the flange and avoid touching the inside surface.
  • Page 38: Shipping Instructions

    Shipping Instructions Use the following procedure when returning a unit to the factory: 1. Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of the Vicon employee who issued the R.A.
  • Page 39: Cable Recommendations

    Cable Recommendations Coaxial Cable Caution: Careful selection of proper cable is essential to obtain the best performance from this equipment. Vicon assumes no responsibility for poor performance when cables other than those recommended, or equivalent, are installed. In all cases, coaxial cable impedance should be 75 ohms.
  • Page 40 Twisted-Pair Cable CAUTION: Careful selection of the proper cable is essential to obtain the best performance from this equipment. Vicon assumes no responsibility for poor performance when cables other than those recommended are installed. Materials Use a pure copper stranded conductor with or without a tin plating to obtain a low DC resistance. Do not use cable with either a steel or an aluminum stranded conductor because these do not transfer signals effectively for long distances.
  • Page 41 Network Cable Caution: Careful selection of proper cable is essential to obtain the best performance. Vicon assumes no responsibility for poor performance when cables other than the recommended types, or equivalent, are used. Materials Use pure copper stranded conductors to obtain a low DC resistance. The preferred insulation and cable jacket is Polyvinyl chloride (PVC).
  • Page 42: Technical Information

    75 ohms. Fuse: F1: 5 x 20 mm, 1.6 A 250 VAC, slo-blo. F2: 5 x 20 mm, 2.5 A 250 VAC, slo-blo. Radio Frequency Emission Rating: FCC Class A. 34 • Technical Information XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 43 Screen Titling Capabilities: Variety of camera ID information is software programmable. Programmable for camera, preset, sector, relay and alarms. Camera: 1 for each. Preset: 79 maximum. Sector: 16 maximum. Technical Information • 35 XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 44 Koninklijke Philips Electronics N.V. Kalatel is a trademark of GE Interlogix. Ultrak is a trademark of Honeywell Inc. Cohu is a trademark of Cohu, Inc. Panasonic is a registered trademark of Matsushita Electric Industrial Co., Ltd. 36 • Technical Information XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 45 Housing: plastic, cast aluminum. Trim Ring: cast zinc/aluminum Finish: Paint. Color: White housing and sunshield; black trim ring. Operating Pressure: 1 - 5 psi (0.07 - 0.34 atm or bars) maximum. Technical Information • 37 XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 46 Maintained Temperature and Humidity Range: 14° F (-10° C) to 140° F (60° C) maximum. Up to 90% relative, noncondensing. Ingress Protection: EN60529, IP 67 rated. Figure 10 Dimensions 38 • Technical Information XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing...
  • Page 47: Vicon Standard Equipment Warranty • 39

    Software supplied either separately or in hardware is furnished on an “As Is” basis. Vicon does not warrant that such software shall be error (bug) free. Software support via telephone, if provided at no cost, may be discontinued at any time without notice at Vicon’s sole discretion.
  • Page 48 Vicon Industries Inc. Corporate Headquarters 89 Arkay Drive Hauppauge, New York 11788 631-952-CCTV (2288) 800-645-9116 Fax: 631-951-CCTV (2288) Vicon Europe Headquarters Brunel Way Fareham, PO15 5TX United Kingdom +44(0) 1489/566300 Fax: +44(0) 1489/566322 Germany vin-videotronic infosystems gmbh Lahnstrasse 1 D-24539 Neumuenster...

Table of Contents