CLEAR PROGRA M O PTI ONS (AD DRESS 1197 & 1198)
1197 XX
GEM-RP1CAe2 Keypad
1197 XX
GEM-RP2ASe2 Keypad
1198 XX
GEM-RP1CAe2 Keypad
1198 XX
GEM-RP2ASe2 Keypad

USER PROGRAM MODE

PRELIMINARY INFORMATION

The User Program Mode is covered in detail in the operating instructions for the keypad in use.
!
Only Keypad #1 may be used for programming, however this keypad may be located in any area.
!
The Program Mode cannot be accessed while the communicator is transmitting except during the first three minutes after power-up.
!
After entering codes or data, press the save
!
If the keypad is in the Program Mode and no activity is detected for longer than 4 minutes, a steady tone will sound.
!
Press the
C
button to silence the sounder and exit the User Program Mode.
If a GEM-RP2ASe2 or GEM-K2AS keypad is used, configure address jumpers as Keypad #1 (see the section of this manual
Configuring the GEM-RP2ASe2/GEM-K2AS Keypad). Use the
each programming line.
NOTE: For ease of programming, it is recommended that a GEM-RP1CAe2 or GEM-K1CA be used as Keypad #1. (A new GEM-
RP1CAe2/GEM-K1CA is automatically configured as Keypad #1). See Keypad Configuration Mode and WI897 for more information.
ACCESSING USER PROGRAM MODE
1. Press EEEEEE
New Panel (Default User Code = 123)
Existing Panel (Any Code with User Program Option Enabled)
2. Press Q
Until "TURNON PROG Y/N" (GEM-RP2ASe2/GEM-K2AS) or "17" (GEM-RP3DGTL/GEM-K3DGTL or
GEM-RP4RFC/GEM-K4RF) appears on the LCD screen.
3. Press P
To Enter User Program Mode.
4. Press C
To Exit User Program Mode when finished.
L
NAPCO Security Systems
Clear Dealer Program (Erases Dealer Program)
This erases the dealer program. Use this feature to start a
customized default program. Program Data and System
Status Memory is erased where Scheduled Data and Zone
Descriptions are maintained.
Access address 1197, then press the
NOTE: Enter Easy Menu Driven Program Mode to program system again.
Cold Start (Erases Entire Program)
This erases the entire program including Dealer Program
by erasing Program Data, Zone Description Data and
System Status Data (similar to a new panel).
Access address 1198, then press the
NOTE: Some features (schedules) can only be programmed again with the
Downloading Software.
U
button. Data will not be stored into memory unless this button is pressed.
R
or
A
R
X
U
button. Data entry is not allowed.
U
button. Data entry is not allowed.
button to manually scroll the display at the end of
GEM-P1632 Programming Instructions
!
Page 41