NAPCO Gemini GEM-P1632 Programming Instructions Manual page 39

Control panel/communicator with keypads
Table of Contents

Advertisement

Table 1
DATA
RELAY #
ENTRY
blank (•)
NONE
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
Table 2
DATA
TURN OFF
ENTRY
ON AREA
DISARM
blank (•)
NONE
1
Area 1
2
Area 2
3
Area 1 &
Area 2
Table 3
TIMEOUTS
(Alarm Type is selected for
Timeout Type in min. or sec.)
DATA ENTRIES
TIMEOUT
LEFT
RIGHT
blank (•) blank (•)
0 min./sec.
blank (•)
1
1 min./sec.
blank (•)
2
2 min./sec.
blank (•)
3
3 min./sec.
blank (•)
4
4 min./sec.
blank (•)
5
5 min./sec.
blank (•)
6
6 min./sec.
blank (•)
7
7 min./sec.
blank (•)
8
8 min./sec.
blank (•)
9
9 min./sec.
blank (•)
0
10 min./sec.
blank (•)
B
11 min./sec.
blank (•)
C
12 min./sec.
blank (•)
D
13 min./sec.
blank (•)
E
14 min./sec.
blank (•)
F
15 min./sec.
1
blank (•)
16 min./sec.
1
1
17 min./sec.
1
2
18 min./sec.
1
3
19 min./sec.
1
4
20 min./sec.
1
5
21 min./sec.
1
6
22 min./sec.
1
7
23 min./sec.
1
8
24 min./sec.
1
9
25 min./sec.
1
0
26 min./sec.
1
B
27 min./sec.
1
C
28 min./sec.
1
D
29 min./sec.
F
F
255 min./sec.
For a desired delay/timeout not
listed, do the following:
A. Choose a desired delay/
timeout, (ex: 20 min.)
B. Divide it by 16
1 Quotient
Left Digit
16 20
16
4 Remainder
Right Digit
L
NAPCO Security Systems
RELAY EVENT OPTIONS
RELAY #
AREA
See
See
Table 1 below
Table 2 below
DATA ENTRIES
LEFT
blank (•)
blank (•)
blank (•)
blank (•)
blank (•)
blank (•)
blank (•)
blank (•)
blank (•)
blank (•)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
* NOTE: Keypad Auxiliary is not to be selected for UL Installations.
NOTE: Keypad Tamper must be enabled in UL installations.
TIMEOUT
EVENT ID
See
See
Table 3 below
Table 4 below
Table 5A
RELAY EVENT
ALARM TYPE OPTIONS
LEFT
ALARM
DATA
TYPE
ENTRIES
blank (•)
Burglary
1
Fire
4
Day Zone
8
Burglary
9
Fire
C
Day Zone
Table 4
EVENT ID CODES
OPTION
RIGHT
blank (•)
Area 1 Arm
1
Area 2 Arm
8
Zone 1
9
Zone 2
0
Zone 3
B
Zone 4
C
Zone 5
D
Zone 6
E
Zone 7
F
Zone 8
blank (•)
Zone 9
1
Zone 10
2
Zone 11
3
Zone 12
4
Zone 13
5
Zone 14
6
Zone 15
7
Zone 16
8
Zone 17
9
Zone 18
0
Zone 19
B
Zone 20
C
Zone 21
D
Zone 22
E
Zone 23
F
Zone 24
blank (•)
Zone 25
1
Zone 26
2
Zone 27
3
Zone 28
4
Zone 29
5
Zone 30
6
Zone 31
7
Zone 32
X
GEM-P1632 Programming Instructions
COND.
See
Tables 5A & 5B
below
Table 5B
RELAY EVENT ACTIVATION
CONDITIONS
TIMEOUT
RIGHT
TYPE
DATA
ENTRIES
Minutes
1
Minutes
2
Minutes
3
Seconds
4
Seconds
5
Seconds
Table 4 (cont'd)
EVENT ID CODES
DATA ENTRIES
OPTION
LEFT
RIGHT
3
blank (•)
Area 1 KP Ambush
3
1
Area 1 KP Panic
3
2
Area 1 KP Fire
3
3
Area 1 KP Aux *
3
4
Area 1 KP Tamper
3
5
Area 1 Fail to Open
3
6
Area 1 Fail to Close
3
8
Area 2 KP Ambush
3
9
Area 2 KP Panic
3
0
Area 2 KP Fire
3
B
Area 2 KP Aux *
3
C
Area 2 KP Tamper
3
D
Area 2 Fail to Open
3
E
Area 2 Fail to Close
4
blank (•)
Test Timer
4
3
Memory Fail
4
4
Low Battery
4
5
AC Fail
4
6
EZM Tamper
4
7
Alarm Supervisory
4
D
RF Receiver Trouble (Tamper/Fail)
4
E
Wireless TX Tamper
4
F
Wireless TX Trouble (LB/Supervisory)
C
8
Area 1 Arming AWAY
C
9
Area 2 Arming AWAY
D
blank (•)
Keypad Fail
D
1
EZM Fail
D
2
Quickloader Device Control
D
5
General System Alarm
D
8
Area 1 General System Alarm
D
9
Area 2 General System Alarm
F
blank (•)
Relay Control Group 1
F
1
Relay Control Group 2
F
8
Entry Relay Area 1
F
9
Entry Relay Area 2
!
Page 39
OPTIONS
Alarm
Restore
Trouble
Trouble Restore
Follow Zone

Advertisement

Table of Contents
loading

Table of Contents