Setting Default Fade Times - ETC Express 24/48 User Manual

Two scene preset lighting control system
Hide thumbs Also See for Express 24/48:
Table of Contents

Advertisement

Setting default fade times

6.
The factory-set default fade time is five seconds.
24
The console assumes default values for upfade and downfade times, but
you can change them. Change all fade times at once by changing the
default values, as explained below. You can also change fade times
individually as explained under
page
85, and also under
Fade times may be programmed from 0.1 seconds to 99:59 minutes. The
number may be entered in normal time format or in decimal format. When
entered with a decimal point, the number must be less than one minute
(0.1 to 59.9 seconds) to be accepted. When entered without a decimal
point, a 2-digit number will be treated as seconds if less than 60 and as a
calculated value of minutes and seconds if between 60 and 99. For
example, if you enter 70, the time will display as 1:10. If you enter either
a 3-digit or a 4-digit number, the last two digits, up to 59, are interpreted
as seconds. For example, if you enter 9930, the time will display as 99:30.
Follow these steps to assign new default fade times.
Keystrokes:
1. Press [Setup].
2. Select [1], System
Settings, and press
[Enter].
3. Select [3], Default Fade
Time, and press [Enter].
4. Press [6] to enter a six
second upfade time.
5. Press [Enter].
6. Press [3] to enter a three
second downfade time.
7. Press [Enter].
a. If you want the upfade and downfade times to be the same,
skip steps 6 and 7. The downfade would take whatever value
you assigned to the upfade time in step 4.
Recording a cue with a single fade time,
Recording a cue with split fade times, page
Action:
Selects Setup display
Selects System Settings menu
Prompt reads:
Enter default up fadetime
Corner reads:
UpTime 6
Prompt reads:
Enter default down fadetime
Corner reads:
a
DnTime 3
Fade times are reset
6
86.
Chapter 3 System settings

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express 48/96Express 72/144

Table of Contents