Set grandmaster type

Set channels / submasters 1-to-1

28
You may set the Master slider to one of four control options.
Disabled
Grandmaster
Sub Grandmaster
Scenemaster
To configure your Grandmaster, follow these steps:
Keystrokes:
1. Press [Setup].
2. Press [1], System Settings,
[Enter].
3. Press [1][0], Master Type,
[Enter].
4. Press [1] [Enter].
Set Channels / Submasters 1-to-1 sets your console's channels to a one-
to-one match with your submasters. Thus, channel 1 is patched to
submaster 1, channel 2 to submaster 2, and so on. Channel levels are set
to Full and up/dwell/down times are set to 0/Manual/0.
To reset your channels and submasters, follow these steps:
Keystrokes:
1. Press [Setup].
2. Press [1], System Settings,
[Enter].
3. Press [1][1], Set Channels/
Submasters 1-to-1, [Enter].
4. Press [Enter].
Master slider does nothing.
Master slider controls all levels on stage
except parked channels and independent
channels.
Master slider controls all levels on stage
set by submasters.
Master slider controls all levels on stage
set by the channel sliders.
Action:
Displays Setup menu
Displays System Settings
menu
Prompt reads:
Select master type and
press ENTER (0 = Disabled,
1 = Grandmaster,
2 = Sub Grandmaster,
3 = Scenemaster)
Master is set as Grandmaster
Action:
Displays Setup menu
Displays System Settings
menu
Prompt reads:
Select page to default, then
press ENTER (0 = All pages)
Channels are assigned to
submasters. The display
returns to Setup menu
Chapter 3 System settings