Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WATER INLET / ATC SENSOR
Refer to page 4-7 for the procedure for access-
ing the water inlet/ATC sensor.
Solenoid
Terminals
1.
Unplug washer or disconnect power.
2.
To test a solenoid coil:
a) Disconnect the solenoid connector from
the water inlet you are testing.
b) Set the ohmmeter to the R x 1 scale.
c) Touch the ohmmeter test leads to the
solenoid terminals. The meter should
indicate between 740 and 820 Ω.
ATC Sensor
Terminals
WARNING
Electrical Shock Hazard
3.
To test the ATC sensor:
a) Disconnect the wires from the sensor
terminals.
b) Touch the ohmmeter test leads to the
sensor terminals. The meter should in-
dicate as shown in the following "Sen-
sor Resistance Chart."
SENSOR RESISTANCE CHART
Temperature
(
F)
ο
40
50
60
70
80
90
100
110
120
130
140
150
5-3
Resistance
(Ohms)
126k-135k
97k-102k
75k-78k
58k-61k
46k-47k
36k-37k
28k-30k
23k-24k
18k-19k
15k-16k
12k-13k
10k-11k