Chapter 2 User Commands

Any system keypad can be used to program or perform any keypad command. LED keypads use status and zone indicator lights to represent
alarm functions and status. The LCD keypad displays the description and status indicator lights represent alarm functions and status. This section
describes basic keypad commands.
[#]
Press the
key to reset the keypad if an error has been made entering user codes or keypad commands.

2.1 Away Arming

The Ready light must be ON to arm the system. If the Ready light is OFF, ensure that all protected doors and windows are secure or
bypassed. To arm the system in the Away mode, either press and hold the Away function button for 2 seconds or enter a valid user code and
leave the premises through a door programmed as Delay. Upon arming, the Armed light will turn ON. If a user code was used to arm the sys-
tem and Stay/Away zones are programmed, the Bypass light will turn ON and will turn OFF when a door programmed as Delay is violated.
If the Audible Exit Delay option is enabled, the keypad will beep once every second during the exit delay (and three times a second during
the last 10 seconds) to prompt the user to leave.

2.2 Stay Arming

The Ready light must be ON to arm the system. If the Ready light is OFF, ensure that all protected doors and windows are secure or
bypassed. To arm the system in the Stay mode, either press and hold the Stay function button for 2 seconds or enter a valid user code and stay
within the premises (do NOT violate a door programmed as Delay). Upon arming, the Armed light and Bypass light will turn ON. If the Stay
function button is used, the keypad will not beep during the exit delay. If a user code was used, the keypad will beep if the Audible Exit
Delay option is enabled.

2.3 Disarming

The user must enter through a door programmed as Delay. Upon entering, the keypad will emit a steady tone (and emit a pulsing tone during
the last 10 seconds of entry delay) to prompt the user to disarm the system. Enter a valid user code to disarm the system. If an alarm occurred
while the panel was armed, the Memory light and the zones that went into alarm will be flashing (LED keypad) or the keypad will display
'Alarm in Memory' (LCD keypad). Press the [#] key to return the keypad to the Ready state.

2.4 [,] Commands

The following is a list of the [,] commands available and a description of each:
[,][1]
Bypass (disarmed state)/Reactivate Stay/Away Zones (armed state)
[,][2]
Display Trouble Conditions
[,][3]
Display Alarm Memory
[,][4]
Door Chime Enable/Disable
[,][5]
User Code Programming
[,][6]
User Commands
[,][7][x]
Command Functions 1 – 4
[,][8]
Installer Programming
[,][9][code]
No-Entry Arming
[,][0]
Quick Arm (disarmed state)/Quick Exit (armed state)
[,][1] Bypass/Re-activate Stay/Away Zones
LED Keypad
Press [,][1] to enter the bypass mode. If the Code Required for the Bypass option is enabled, enter a valid user code. The Bypass light will
flash. The keypad will turn ON the corresponding zone light to indicate a zone is bypassed. To bypass or unbypass a zone, enter the 2-digit
zone number. Once the correct zones are bypassed, press [#] to exit. The Bypass light will be ON if any zones are manually bypassed.
LCD Keypad
Press [,][1] to enter the bypass mode. If the Code Required for the Bypass option is enabled, enter a valid user code. The keypad will dis-
play 'Scroll to View Zones'. The keypad will display the programmed zone labels for the zones and include the letter 'O' in the bottom right
corner if the zone is violated, or the letter 'B' if the zone is bypassed. Scroll to the appropriate zone and press the [,] key to change the
bypass status (or enter the 2-digit zone number). Once the correct zones are bypassed, press [#] to exit.
Additional Bypass Commands:
Bypass Recall:
Clear Bypass:
Save Bypass:
Recall Save:
Hold-up Zones cannot be assigned to bypass groups.
Re-activate Stay/Away Zones: Press [,][1] when the system is armed in the Stay mode to change the armed status to Away mode. The
system will add the Stay/Away zones back into the system after the exit delay time expires.
Press [99]. The keypad will recall the last group of zones that were bypassed
Press [00]. The keypad will clear the bypass on all zones.
Press [95]. The keypad will save which zones are manually bypassed.
Press [91]. The keypad will recall the bypassed zones that were saved.
6