[367]-[374] Opening/Closing Communicator Call Directions
Option 1
Section Partition
1st Telephone
Number (Def OFF)
[367]
1
I________I
[368]
2
I________I
[369]
3
I________I
[370]
4
I________I
[371]
5
I________I
[372]
6
I________I
[373]
7
I________I
[374]
8
I________I
[375] System Maintenance Communicator Call Directions
Option 1
Section Partition
1st Telephone
Number (Def ON)
[375]
I________I
[376] System Test Transmissions Communicator Call Directions
Option 1
Section Partition
1st Telephone
Number (Def ON)
[376]
I________I
[377] Communication Variables
The values in
gray
are required for CP-01 compliant systems.
Default
003
0
0
1
I___
__I__
__I___
__I
003
0
0
3
I___
__I__
__I___
__I
003
0
0
3
I___
__I__
__I___
__I
000
0
3
0
I___
__I__
__I___
__I
030
0
3
0
I___
__I__
__I___
__I
010
0
1
0
I___
__I__
__I___
__I
030
0
3
0
I___
__I__
__I___
__I
030
0
3
0
I___
__I__
__I___
__I
007
0
0
7
I___
__I__
__I___
__I
030
0
3
0
I___
__I__
__I___
__I
000
0
0
5
I___
__I__
__I___
__I
* For UL installations, the Entry Delay plus Communication Delay time must not exceed 60 seconds.
**Dependent on programming in [382], Option [6].
***Dependent on programming in [702], Option [3].
****Dependent on programming in [380], Option [8].
[378] Test Transmission Time of Day
Default
9999
I_______I_______I_______I_______I
[379] Periodic DLS Time of Day
Default
FFFF
I_______I_______I_______I_______I
Option 2
2nd Telephone
Number (Def OFF)
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
Option 2
2nd Telephone
Number (Def OFF)
I________I
Option 2
2nd Telephone
Number (Def OFF)
I________I
Swinger Shutdown (Alarms and Rest)
Swinger Shutdown (Tampers and Rest)
Swinger Shutdown (Maintenance and Rest)
Communication Delay*
AC Failure Communication Delay
TLM Trouble Delay
Test Transmission Cycle (land line)
For Future Use
Zone Low Battery Transmission Delay
Delinquency Transmission Cycle
Communications Cancelled Window
Valid entries are 0000-2359 (9999 to disable)
Valid entries are 0000-2359 (9999 for Random; FFFF to disable)
Option 3
Option 4
Not Used
Not Used
(Def OFF)
(Def OFF)
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
Option 3
Option 4
Not Used
Not Used
(Def OFF)
(Def OFF)
I________I
I________I
Option 3
Option 4
Not Used
Not Used
(Def OFF)
(Def OFF)
I________I
I________I
001-014 Transmissions; 000=disabled
001-014 Transmissions; 000=disabled
001-014 Transmissions; 000=disabled
000-255 seconds
001-255 hours/minutes**; 000=disabled
No. of checks required - valid entries 003 - 255
001-255 days/minutes***
000-255 days
000-255 days/hours****
000-255 minutes
45
Chapter 5 Programming Worksheets
Option 5
Options 6,7,8
Alt Comm
Future Use
(Def OFF)
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
Option 5
Options 6,7,8
Alt Comm
Future Use
(Def ON)
I________I
I________I
Option 5
Options 6,7,8
Alt Comm
Future Use
(Def ON)
I________I
I________I