[380] First Communicator Option Code
Option Description
[1]
the system communicator is enabled.
ON:
OFF:
the communicator is disabled.
the system transmits alarm restorals if the zone is restored and the bell has timed out.
[2]
ON:
OFF:
the system transmits alarm restorals immediately when the zone is restored.
the panel uses rotary (pulse) dialing. OFF: the panel uses DTMF (touchtone) dialing.
[3]
ON:
[4]
the panel will switch from DTMF dialing to rotary dialing after the 4th failed attempt to communicate.
ON:
the panel will use DTMF dialing for all dialing attempts.
OFF:
[5]
the system uses the Third Phone Number to back up the First Phone Number.
ON:
the Third Phone Number is disabled.
OFF:
[6]
the system alternates between the First Phone Number and Third Phone Number when attempting to report an event.
ON:
the panel will dial the First Phone Number for the programmed number of attempts, then switch to the Third Phone Number.
OFF:
[7]
For Future Use
[8]
ON:
the Delinquency feature follows zone activity.
[381] Second Communicator Option Code
Option
Description
[1]
ON
: the keypad beeps 8 times after successfully transmitting the Opening After Alarm reporting event.
: the keypad does not beep.
OFF
[2]
ON
: the bell output squawks 8 times after successfully transmitting the Opening After Alarm reporting event.
: the bell output does not activate.
OFF
[3]
ON
: the system uses programmed reporting codes when transmitting using the SIA format.
: the system automatically generates all reporting codes transmitted.
OFF
[4]
ON
: the system beeps the keypad 8 times after successfully transmitting a Closing reporting event.
: the keypad does not beep.
OFF
[5]
ON
: the system requests a Listen in/two-way session the next time it calls the 1st/3rd Phone Number when the PC59xx transmits a request.
: the system ignores the request from the PC59xx.
OFF
This option is used with PC59xx series modules.
[6]
: the system requests a Listen in/Two-way session the next time it calls the 2nd Phone Number when the PC59xx transmits a request.
ON
OFF
: the system will ignore the request from the PC59xx.
This option is used with PC59xx series modules.
: the system uses Contact ID format programmed reporting codes when transmitting reporting codes.
[7]
ON
: the system automatically generates all reporting codes transmitted.
OFF
[8]
ON
: the system will follow ULC Communication Priority.
: the system will follow standard communications priority.
OFF
[382] Third Communicator Option Code
Option
Description
For Future Use
[1]
[2]
: the system will transmit all alarms during Walk Test.
ON
[3]
: the keypad will display the message 'Communications Cancelled' (programmable LCD) or 'CC' (fixed-message LCD) upon
ON
successful transmission of the Communication Cancelled reporting event.
: the keypad will not display these messages.
OFF
[4]
: the system dials the Call Waiting Cancel String on the first attempt to dial the central station.
ON
: the system does not dial the Call Waiting Cancel String.
OFF
[5]
: enables support for the TL/GS Module.
ON
: the AC Failure Transmission Delay Timer is in hours.
[6]
ON
[7]
ON
: sets the number of Dialing attempts to 1 when using Residential Dial Format.
: residential Dial follows Dialing Attempt Counter.
OFF
[8]
For Future Use
OFF:
the Delinquency feature follows arming.
: the system will not report alarm events during Walk Test.
OFF
: disables TL/GS Module.
OFF
: the delay is in minutes.
OFF
21