DSC PowerSeries PC1616 Installation Manual page 59

V4.6 na security system
Hide thumbs Also See for PowerSeries PC1616:
Table of Contents

Advertisement

PowerSeries - PC1616/PC1832/PC1864
Section #
Reporting Code
[345]-[346]
TLM Failure/Restore
[345]-[346]
Gen System Trouble/Rest.
[345]-[346]
Gen System Supervisory
Trouble/Rest.
[346]
Cold Start (System Reset)
[347]
Phone# 1 or 2 FTC Restoral Control panel has restored communications to central station on
[347]
Event Buffer is 75% Full
[347]
DLS Lead In
[347]
DLS Lead Out
[347]
Zone Fault/Rest.
[347]
Delinquency
[347]
Wireless Device Low Battery
Trouble/Rest.
[347]
Installer Lead In/Lead Out
[348]
Walk Test End/Begin
[348]
Periodic Test with Trouble
[348]
Periodic Test
[348]
System Test
[349]
PC5700 Ground Fault Trouble/
Rest
[349]
PC5700 TLM Line 1 Trouble/Rest. TLM Trouble /Restore occurs on the PC5700
[349]
PC5700 TLM Line 2 Trouble/Rest. TLM Trouble /Restore occurs on the PC5700
[601]-[604]
Closings
[605]-[608]
Openings
*
A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
**
UU = user number (User 01-95); ZZ = zone number (01-64)
***
Use the "Fail to close" event code [(4)54] to report closing or activity delinquency. Ensure the central station is aware that this code is used.
****
Zones are identified, panic pendants, wireless keys, and handheld keypads are not.
Table 2: Contact ID Programmed Zone Alarm/Restoral Event Codes
(as per SIA DCS: 'Contact ID' 01-1999): Program any of these codes for zone
alarms/restorals when using the standard (non-automatic) Contact ID reporting
format.
Medical Alarms
(1)34 Entry / Exit
(1)AA Medical
(1)35 Day / Night
(1)A1 Pendant Transmitter
(1)36 Outdoor
(1)A2 Fail to Report In
(1)37 Tamper
Fire Alarms
(1)38 Near Alarm
General Alarms
(1)1A Fire Alarm
(1)11 Smoke
(1)4A General Alarm
(1)12 Combustion
(1)43 Exp. module failure
(1)13 Water Flow
(1)44 Sensor tamper
(1)14 Heat
(1)45 Module Tamper
(1)15 Pull Station
(1)4A Cross Zone Police Code
24 Hour Non-Burglary
(1)16 Duct
(1)17 Flame
(1)5A 24 Hour non-Burg
(1)18 Near Alarm
(1)51 Gas detected
Panic Alarms
(1)52 Refrigeration
(1)2A Panic
(1)53 Loss of Heat
(1)21 Duress
(1)54 Water Leakage
(1)22 Silent
(1)55 Foil Break
(1)23 Audible
(1)56 Day Trouble
Burglar Alarms
(1)57 Low bottled Gas level
(1)3A Burglary
(1)58 High Temp
(1)31 Perimeter
(1)59 Low Temp
(1)32 Interior
(1)61 Loss of Air Flow
(1)33 24 Hour
Code Sent When...
Telephone line monitoring trouble/Telephone line restored
"Service Required" trouble (view troubles using [*][2])/trouble
restored
Control panel loses/restores communications with module(s)
connected to the Keybus
The system has been restarted after a total power loss. The reporting
code is sent after a 2 minute start-up delay
Phone# 1 or 2 (after FTC)
Event buffer is almost full since last upload
Downloading session start
Downloading session complete
One or more zones have faults/restored
Programmed amount of time (days or hours) for delinquency has
expired without zone activity, or without system being armed
Wireless zones, panic pendants, handheld keypads, wireless keys
have low battery/all low batteries restored
Installer's mode has been entered/exited
End of test/Beginning of test
Periodic system test transmission with trouble
Periodic system test transmission
[*][6] bell/communications test
Ground/Fault/Trouble occurs on the PC5700
System armed (user 33-95 indicated)
System disarmed (user 33-95 indicated)
Table 3: Automatic Zone Alarm/Restoral Codes
Zone Definition
Delay 1
Delay 2
Instant
Interior
Interior Stay/Away
Delay Stay/Away
Delayed 24-Hr Fire
Standard 24-Hr Fire
24-Hr Supervisory
24-Hr Supervisory Buzzer
24-Hr Burglary
24-Hr Holdup
24-Hr Gas
24-Hr Heat
24-Hr Auxiliary (Medical)
24-Hr Panic
24-Hr Emerg. (non-medical)
24-Hr Sprinkler
24-Hr Water
24-Hr Freeze
24-Hr Latching
Interior Delay
Auto Verified Fire
24-Hr Fire Supervisory
Day Zone
Instant Stay/Away
24-Hr Bell/Buzzer
24-Hr Non-latching Tamper
Night Zone
Delayed 24-Hr Fire (Wireless)
Standard 24-Hr Fire(Wireless)
24-Hr CO Alarm
* ZZ or ZZZ= zones 01-64
56
Automatic
Dialer
SIA Auto
Contact ID
Direction*
Rep Codes**
Codes
MA/R
E(3)51-000/
LT-01/LR-01
R(3)51-000
MA/R
E(3)AA-000/
YX-00/YZ-00
R(3)AA-000
MA/R
E(3)3A-000/
ET-00/ER-00
R(3)3A-000
MA/R
R(3)A5-000
RR-00
MA/R
R(3)54-000
YK-00
MA/R
E(6)22-000
JL-00
MA/R
E(4)11-000
RB-00
MA/R
E(4)12-000
RS-00
MA/R
E(3)8A-ZZZ/
UT-ZZ/UJ-ZZ
R(3)8A-ZZZ
MA/R
E(6)54-000*** CD-00
MA/R
E(3)84-000/
XT-00/XR-00
R(3)84-000
XT-ZZ/XR-ZZ****
MA/R
E(6)27-000/
LB-00/LS-00
E(6)28-000
T
R(6)A7-UUU/
TE-00/TS-00
E(6)A7-UUU
T
E(6)A8-000
RY-00
T
E(6)A2-000
RP-00
T
E(6)A1-000
RX-00
MA/R
E(3)1A-000
US-00/UR-00
MA/R
E(3)51-000/
LT-01/LR-01
R(3)51-000
MA/R
E(3)52-000/
LT-02/LR-02
R(3)52-000
O/C
R(4)A1-UUU CL-UU
O/C
E(4)A1-UUU
OP-UU
SIA Auto Rep
Contact ID
Codes*
Alarm Auto
Rep Codes*
BA-ZZ/BH-ZZ
E(1)3A-ZZZ
BA-ZZ/BH-ZZ
E(1)3A-ZZZ
BA-ZZ/BH-ZZ
E(1)3A-ZZZ
BA-ZZ/BH-ZZ
E(1)3A-ZZZ
BA-ZZ/BH-ZZ
E(1)3A-ZZZ
BA-ZZ/BH-ZZ
E(1)3A-ZZZ
FA-ZZ/FH-ZZ
E(1)1A-ZZZ
FA-ZZ/FH-ZZ
E(1)1A-ZZZ
US-ZZ/UR-ZZ
E(1)5A-ZZZ
UA-ZZ/UH-ZZ
E(1)5A-ZZZ
BA-ZZ/BH-ZZ
E(1)3A-ZZZ
HA-ZZ/HH-ZZ
E(1)22-ZZZ
GA-ZZ/GH-ZZ
E(1)51-ZZZ
KA-ZZ/KH-ZZ
E(1)58-ZZZ
MA-ZZ/MH-ZZ
E(1)AA-ZZZ
PA-ZZ/PH-ZZ
E(1)2A-ZZZ
QA-ZZ/QH-ZZ
E(1)A1-ZZZ
SA-ZZ/SH-ZZ
E(1)13-ZZZ
WA-ZZ/WH-ZZ
E(1)54-ZZZ
ZA-ZZ/ZH-ZZ
E(1)59-ZZZ
UA-ZZ/UH-ZZ
E(1)4A-ZZZ
BA-ZZ/BH-ZZ
E(1)3A-ZZZ
FA-ZZ/FH-ZZ
E(1)1A-ZZZ
FS-ZZ/FV-ZZ
E(2)AA-ZZZ
BA-ZZ/BH-ZZ
E(1)3A-ZZZ
BA-ZZ/BH-ZZ
E(1)3A-ZZZ
UA-ZZ/UH-ZZ
E(1)5A-ZZZ
UA-ZZ/UH-ZZ
E(1)4A-ZZZ
BA-ZZ/BH-ZZ
E(1)3A-ZZZ
FA-ZZ/FH-ZZ
E(1)1A-ZZZ
FA-ZZ/FH-ZZ
E(1)1A-ZZZ
GA-ZZ/GH-ZZ
E(1)62-ZZZ
Contact ID
Rest. Auto
Rep Codes
R(1)3A-ZZZ
R(1)3A-ZZZ
R(1)3A-ZZZ
R(1)3A-ZZZ
R(1)3A-ZZZ
R(1)3A-ZZZ
R(1)1A-ZZZ
R(1)1A-ZZZ
R(1)5A-ZZZ
R(1)5A-ZZZ
R(1)3A-ZZZ
R(1)22-ZZZ
R(1)51-ZZZ
R(1)58-ZZZ
R(1)AA-ZZZ
R(1)2A-ZZZ
R(1)A1-ZZZ
R(1)13-ZZZ
R(1)54-ZZZ
R(1)59-ZZZ
R(1)4A-ZZZ
R(1)3A-ZZZ
R(1)1A-ZZZ
R(2)AA-ZZZ
R(1)3A-ZZZ
R(1)3A-ZZZ
R(1)5A-ZZZ
R(1)4A-ZZZ
R(1)3A-ZZZ
R(1)1A-ZZZ
R(1)1A-ZZZ
R(1)62-ZZZ

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerseries pc1832Powerseries pc1864