DSC PowerSeries PC1616 Installation Manual page 27

V4.6 na security system
Hide thumbs Also See for PowerSeries PC1616:
Table of Contents

Advertisement

PowerSeries - PC1616/PC1832/PC1864
PGM Output Option [29] and [35]-[41]
Option
Description
[1]-[2]
For Future Use
[3]
ON
: the PGM will switch to ground when the event occurs.
: the PGM will switch to open when the event occurs.
OFF
[4]-[7]
For Future Use
[8]
ON
: AND logic is selected, all zones that are enabled must be violated before the PGM will activate.
: OR logic is selected, only one violated zone is required to activate the PGM. All zones must be restored to turn it OFF.
OFF
Zones are assigned to this PGM in the PGM Partition Assignment Section [551]-[564]
[551] to [564] PGM Partition Assignment
These sections are used to customize the operation of the PGM outputs ([551] for PGM 1, [552] for PGM 2, etc.). Turn on the desired option
in the correct section to assign the PGM output to a specified partition. PGM outputs can be assigned to more than one partition. For PGM
outputs that are considered 'system' outputs (e.g.,Trouble output), programming in these sections will not affect the operation of the PGM
output. Zone Follower PGM types 29 and 35-41 are used to assign specific zones to the PGM.
Each Command Output PGM type can be assigned to one partition only.
[601] to [608] Additional Reporting Codes
Program the reporting code for all events to be transmitted. For information of when each reporting event will be transmitted, refer to
Appendix A – Reporting Codes. The panel also supports Automatic SIA and Automatic Contact ID reporting. Program data [00] to disable
the reporting of an event. If any other data is programmed (Data [01] to [FF]) the panel will automatically generate the correct reporting
event when transmitting to the central station. For all formats excluding Automatic SIA and Automatic Contact ID, the panel will not attempt
to report an event if data [00] or data [FF] is programmed for the reporting code.
[681] to [688] Auto-Disarm Schedules
Program the time to auto-disarm ([681] for Partition 1, [682] for Partition 2, etc.) for each day of the week. Each section has seven, 4-digit
entries: two digits for the hour, two digits for the minute, for Sunday through Saturday. Program using the twenty-four-hour system (for
example, to auto-arm at 8:00 pm program data [20][00]). Valid entries are [00][00] to [23][59] – program [99][99] to disable auto disarming
[691] to [698] Auto-Disarm Holiday Schedule
Program the dates to be used for the Auto-Disarm holiday schedule ([691] for Partition 1, [692] for Partition 2, etc.) Each section has 14, 6-
digit entries: two digits for the month, two digits for the day and two digits for the year. The panel will not disarm on the programmed dates.
The format of entering the date is MMDDYY. Program [99][99][99] to disable the Auto-Disarm holiday schedule.
[700] Automatic Clock Adjust
Program the number of seconds for the last minute of the day. This can be used to make minor corrections to the clock if the AC frequency is
not reliable. Valid entries are [01] to [99].
[701] First International Option Code
Option
Description
[1]
: configures the system for 50Hz AC.
ON
: the system uses the internal crystal for the internal panel clock.
[2]
ON
[3]
: the system will inhibit arming if a Low Battery or AC trouble condition is present.
ON
[4]
: all Tamper troubles will latch and arming will be inhibited. Enter Installer Programming to clear the trouble condition and return
ON
to normal operation.
[5]
: all access codes are 6-digits long.
ON
[6]
: the system will hang up if a busy tone is detected. This attempt is not counted towards the Maximum Dialing Attempts.
ON
OFF
: the panel will not detect busy tones.
[7]
: the system will charge the battery at approximately 700mA.
ON
[8]
: the system will abort a DLS session, Escort access, Listen In/Two-way session if a new central station communication event occurs.
ON
: non-critical events (Test transmission, Periodic Test and System Test) will not abort the session. Events will be communicated after
OFF
the session is complete.
: configures the system for 60Hz AC.
OFF
OFF
: Tamper troubles will not latch and will not inhibit arming.
: all access codes are 4-digits long.
OFF
: the system uses the AC frequency for the internal panel clock.
OFF
OFF
: the system will charge the battery at 400mA.
OFF
24
: arming will not be inhibited.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerseries pc1832Powerseries pc1864

Table of Contents