PowerSeries - PC1616/PC1832/PC1864
[903] View Module Supervision
The keypad will display the modules detected by the system by turning on the associated zone light (LED keypads), flashing the numbers
(fixed-message LCD keypads), or displaying the modules detected in plain language (programmable LCD keypads). Refer to the chart
below:
Indicator Light (Zone)
[01] to [08]
[09] to [14]
[15]
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[24]
[26] to [29]
[904] Wireless Placement Test
Enter [904] followed by the 2-digit number of the wireless zone to test. When a wireless signal is received from the selected transmitter, the
system will indicate the location as Good or Bad, as follows:
:
One bell squawk, 1 keypad beep, keypad zone light [1] ON
Good
:
Three bell squawks, 3 keypad beeps, keypad zone light [3] ON
Bad
Press [#] to exit when testing is complete. Enter the 2-digit zone number for the next wireless device to test or press [#] to return to standard
programming.
[989] Default Master Code
Enter [989][Installer Code] to default the Master Code to the factory defaults.
[990] Installer Lockout Enable
Enter [990][Installer Code][990] to enable the Installer Lockout feature. A hardware default cannot be performed when the Installer Lockout
feature is ON. In addition, the system will chatter the line seizure relay 10 times if the panel is powered up, indicating that the feature is ON.
[991] Installer Lockout Disable
Enter [991][Installer Code][991] to turn the Installer Lockout feature OFF.
[993] to [999]: Factory Default Module/Panel
The following options can be used to restore a module or the main control panel to its factory default settings. Enter the appropriate option,
followed by the Installer Code, followed by the option number (e.g., [993][Installer Code][993])
[993]: Factory Default Alternate Communicator
[995]: Factory Default Escort 5580 Module
[996]: Factory Default Wireless Receiver
[997]: Factory Default PC5400 Module
[998]: Factory Default PC59xx Module
[999]: Factory Default Main Control Panel
Hardware Reset (Default) Main Control Panel
Perform the following to restore the main control panel to its default settings:
1.
Power down the system.
2.
First removing all wires between Zone 1 and PGM1 on the control panel, connect a short between them.
3.
Power up the control panel (AC power only) for 10 seconds.
4.
Power down the control panel, remove the short between Zone 1 and PGM1.
5.
Power up the control panel.
Module
Keypad in Slot #1 to #8
PC5108 Zone Expander #1 to #6
PC5100 Module
PC5108 Zone Expander #7
RF5132 Module or RFK keypad with integrated wireless receiver
PC5208
PC5204 Module
PC5400 Module
PC59xx Module
Alternate Communicator
Escort5580 or Escort5580TC
PC5200 #1 to #4
26