Item
1
Alarm 1/Alarm 2
Message Packet
Alarm FTP
2
Relay Alarm
• Alarm Output
• Go to a preset position
• Return Mode
• Interval
• Black & White
• Message Packet
• Alarm FTP
3
Retry (1 to 3)
4
List
(Continued)
For setting whether to send alarm packets to the PC when there
is alarm input.
Not Available : Do not send alarm packets.
Available
: Send alarm packets.
For operation according to the [Alarm FTP] in the FTP Client
feature when there is alarm input. Please refer to FTP Client
Settings (
Page 47) for details on alarm FTP.
Set Values: Available, Not Available
Set here to enable the relay alarm function, which is activated
when 2 alarms are received within a preset time interval.
The sequence and time interval for the alarm input can be specified.
When [Alarm Output] is selected, alarm signal output will be
sent to the alarm output terminal on the ceiling mount accord-
ing to the output port settings.
Notes
• A second alarm input enables this relay alarm function,
and alarm will not be activated for this second input.
• Unless the alarm output in the "Alarm Output" tab is
enabled, this function will not be activated even if alarm
output is selected in the alarm input settings. (
* Please refer to the [Alarm 1/2] item for details on the set val-
ues.
For setting the no. of times alarm notification is to be sent to
the "V.Networks Controller". (Set Value: 1 to 3)
Note
• Alarm notification may fail, depending on the LAN
environment in use. If it fails, set the value for alarm
notification to "3". In this case, alarm by the "V.Networks
Controller" itself is set off only once.
Press here to display the IP address of the PCs to which an
alarm notification is sent. ("Distribution Address List" Screen)
To delete a distribution address, select the IP address to de-
lete, followed by pressing the Delete button.
Notes
• The list allows setting of up to 10 addresses.
• Message packets will not be sent out when there are 11 or
more addresses.
Function/Set Value
Initial Value
Not Available
Not Available
Not Available
Page 39)