Photon User Guide 412-0035-00-10 Version 100
Test-Pattern Mode: A Test-Pattern mode is provided to verify camera electronics.
1. Off. No test-pattern is provided in this mode. This is the normal mode for viewing
thermal imagery.
2. Ramp. In this ramp mode, the test pattern shown in Figure 17 is provided at the analog
and digital data channels.
pix(0,0) = 0
(Digital values shown apply to the optional 14-bit digital data stream.)
Note: The ramp test pattern is intended primarily for verifying the output of the digital data
channel. The pattern will not necessarily look as shown in Figure 17 when displayed on an
analog video monitor, particularly if an AGC mode other than Automatic is selected.
Figure 17: Ramp test pattern
24
pix(323,0) = 323
pix(183,50) = 16383
pix(184,50) = 0