Photon User Guide 412-0035-00-10 Version 100
1. Disabled Mode: The camera will turn off frame synchronization.
2. Slave Mode: The camera will accept a frame synchronization signal on the interface
connector.
3. Master Mode: The camera will output a frame synchronization signal on the interface
connector when configured as a master.
Note: See the Electrical Interface Control Document (ISC doc. 102-1238-41) for detailed
External Sync requirements.
Save Settings. After using the Control Panel to change all camera modes and settings to
desired values, use the Save Settings command to store your current selections as power-up
defaults. The next time the camera is powered, it will revert to the settings saved as defaults.
Factory Defaults. The Factory Defaults command restores the camera's modes and settings
to the initial values originally specified by the manufacturer, replacing the customized
selections stored used in the Save Settings command.
Reset. The Reset command causes the camera to revert to its power-up default settings just
as if input power was toggled.