Fuses; Ignition Coil - Arctic Cat Prowler Service Manual

Hide thumbs Also See for Prowler:
Table of Contents

Advertisement

4. Using the red tester lead, contact each end of the
fuse holder connector terminals individually.
5. The meter must show battery voltage from one
side of the connector terminal ends.
NOTE: Battery voltage will be indicated from only
one side of the fuse holder connector terminal; the
other side will show no voltage.
NOTE: When testing the HI fuse holder, the head-
light OFF/HI/LO switch must be in the HI position;
when testing the LIGHTS fuse holder, the headlight
dimmer switch can be in either the HI or the LO
position.
NOTE: If the meter shows no battery voltage,
troubleshoot the battery, switches, power distribu-
tion module, or the main wiring harness.
! CAUTION
Always disconnect the battery when performing
resistance tests to avoid damaging the multimeter.
1. Set the meter selector to the OHMS position.
2. Connect the red tester lead to one spade end of the
fuse; then connect the black tester lead to the other
spade end.
3. The meter must show less than 1 ohm resistance.
If the meter shows open, replace the fuse.
NOTE: Make sure the fuses are returned to their
proper position according to amperage. Refer to
the amperage listed under each fuse on the power
distribution module.

Ignition Coil

The ignition coil is mounted on the fuel pump mount-
ing plate adjacent to the fuel pump.
VOLTAGE (Primary Side)
See PEAK VOLTAGE Primary/CDI in this sub-sec-
tion.
Back

Fuses

Back to TOC
RESISTANCE
! CAUTION
Always disconnect the battery when performing
resistance tests to avoid damaging the multimeter.
NOTE: For these tests, the meter selector should
be set to the OHMS position.
Primary Winding
1. Connect the red tester lead to the terminal (with
the wire removed); then connect the black tester
lead to ground.
2. The meter reading must be within specification.
Secondary Winding
1. Connect the red tester lead to the high tension lead
(with the plug cap removed); then connect the
black tester lead to ground.
2. The meter reading must be within specification.
NOTE: If the meter does not show as specified,
replace ignition coil.
Spark Plug Cap
1. Connect the red tester lead to one end of the cap;
then connect the black tester lead to the other end
of the cap.
2. The meter reading must be within specification.
Back to Section TOC
PR278A
5
AR603D
Next
5-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prowler xt2008 prowler xtx

Table of Contents