Sony PMW-RX50 Operating Instructions Manual page 85

Portable memory recorder
Hide thumbs Also See for PMW-RX50:
Table of Contents

Advertisement

Error indications
The recorder informs you of situations where warning, caution, or an operation check is required, through
messages on the LCD monitor, the tally lamps, and a buzzer.
The buzzer is output to the built-in speaker or to the headphones connected via the headphone connector.
The buzzer volume can be set with [Alarm Level] in [Audio Output] (page 49) in the [AUDIO SET] menu.
The recorder stops operation after the following indications.
Error indication on
Buzzer
LCD
E + Error code
Continuous
Warning indications
When one of the following indications is generated, follow the message to clear the problem.
Warning indication
Buzzer
on LCD
Media Near Full
Intermittent
Media Full
Continuous
Battery Near End
Intermittent
Battery End
Continuous
Temperature High
Intermittent
Voltage Low
Intermittent
Insufficient Voltage
Continuous
1)
Intermittent
HDD A
Battery Near
End
1)
Continuous
HDD A
Battery End
Please disconnect
i.LINKNeed to Reboot
Battery Error
Please Change Battery
Backup Battery End
Please Change
Tally
Cause and measures
lamps
Rapidly
The recorder may be defective. Recording stops even if zREC
flashing
is displayed on the LCD monitor.
Turn off the power and check the connected equipment, cables,
and media. If they are not defective, turn on the power again. If
the error persists, consult Sony service personnel.
(If power cannot be turned off by setting the power button to
OFF, remove both the battery pack and the DC IN source.)
Tally
Cause and measures
lamps
Flashing
Free space on the SxS memory cards has become insufficient.
Replace it with another at the earliest opportunity.
Rapidly
No space is left on the SxS memory cards. Recording, clip
flashing
copying and clip division cannot be performed.
Replace it with another.
Flashing
The battery power will be exhausted soon.
Charge the battery pack at the earliest opportunity.
Rapidly
The battery pack is exhausted. Recording cannot be
flashing
performed.
Stop operation and change the battery pack.
Flashing
The internal temperature has risen above a safe operation
limit.
Suspend operation, turn off the power, and wait until the
temperature falls.
Flashing
The DC IN voltage has become low (stage 1).
Check the power supply.
Rapidly
The DC IN voltage is too low (stage 2). Recording cannot be
flashing
performed.
Connect other power source.
Flashing
The battery power of the connected HDD will be exhausted
soon.
Change the battery at the earliest opportunity.
Rapidly
The battery of the connected HDD is exhausted. Recording
flashing
cannot be performed.
Stop operation to change the battery.
You cannot use both an i.LINK connection and an IFU-WLM3
connection at the same time. Turn off the power, and
disconnect one of the connections.
An error was detected with the battery pack.
Replace the battery pack with a normal one.
The remaining power of the backup battery is insufficient.
Replace the battery with a new one.
Troubleshooting
85

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents