Detergent Dispenser Motor & Switch; Inlet Valve Solenoids - KitchenAid KHWS01PMT / WH Technical Education

Front-loading automatic washer
Hide thumbs Also See for KHWS01PMT / WH:
Table of Contents

Advertisement

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
DETERGENT DISPENSER
MOTOR & SWITCH
Refer to page 4-8 for the procedure for servic-
ing the degergent dispenser motor.
1.
Unplug washer or disconnect power.
2.
Disconnect the detergent dispenser mo-
tor and switch connector from the CCU.
3.
Set the ohmmeter to the R x 100 scale.
4.
Touch the ohmmeter test leads to the
indicated wire connector terminals. The
meter should indicate as follows:
Dispenser motor at pins 1 and 3 = 1400
to 1600 Ω.
Dispenser switch at pins 5 and 6 = 0 Ω.
65 3 1
(Connector viewed From Wire End)
WARNING
Electrical Shock Hazard

INLET VALVE SOLENOIDS

Refer to page 4-10 for the procedure for servic-
ing the inlet valves.
1.
Unplug washer or disconnect power.
2.
Disconnect the inlet valve solenoid con-
nector from the CCU.
3.
Set the ohmmeter to the R x 100 scale.
4.
Touch the ohmmeter test leads to the
indicated wire connector terminals. The
meter should indicate between 750 and
850 Ω.
(Connector viewed From Wire End)
5-2
HOT
COLD
7 5 3 1

Hide quick links: