Maintenance And Servicing - WaterLogic WL 1000 GF Technical Manual

Table of Contents

Advertisement

COLD WATER
Push Main button, LED shows green, it dispenses cold water.
AMBIENT WATER
Push Ambient button LED shows red, Push main button
it dispenses ambient water.
HOT WATER
Push hot water button LED shows red, Push Main button,
it dispenses hot water
HOT WATER CAUTION
• Always place cup / mug in the centre of the drip tray.
• Always use a ceramic cup or a cup suitable for use with
hot water.
• Do not hold cup or place hands in dispensing area
whilst dispensing water.
• Do not dispense water in a stop start style of vending
• (Hold the button continuously until cup is full).
• Never try to fill more than one vessel at a time.
22

Maintenance and Servicing

6 MONTH SERVICE PROCEDURE
This procedure should only be carried out by persons trained by Waterlogic
International or their approved distributors. The following instructions covers the
model Hot, Cold, Ambient water. Please remember that carbon filters must be
flushed outside of the machine to waste before connecting to the 1000 GF.
• Every six months the Reverse Osmosis must be back flushed to waste,
the carbon & sediment filters and UV lamp must be changed.
The Reverse Osmosis Membrane must be changed every 24 months.
• The quartz sleeve must be removed, checked and cleaned every six months.
If you remove the quartz sleeve from the cold tank you will need to drain the
header tank first as the tank will still be pressurised from the head of water
stored in the tank
• The 1000GF header tank should be inspected and removed and cleaned
at 6 months
• No paperwork or cleaning records should ever be stored inside the 1000GF.
1. Isolate the power to the WL 1000 GF by turning off the green and red switches
at the rear of the WL 1000 GF and by removing the power cord.
2. To access the Reverse Osmosis filters remove the lower front panel.
3. The 4 stage Reverse Osmosis filters are at the front of the machine mounted on
the filter bracket. All the filters are in-line, mounted in filter clips with push fit pipe
connecters. When changing the carbon filters please pre-flush to waste outside
the machine. It is important that no carbon particles enter the machine or block
the Reverse Osmosis membrane. Replace the sediment filter, the pre-carbon filter,
and the post carbon filter.
4. Drain and inspect the header tank. Remove the tank and clean it.
5. Remove the UV lamp and quartz sleeve. Clean the quartz sleeve; inspect the
black o-ring for damage.
Waterlogic 1000 GF Technical Manual - Issue A, July 2011