Cleaning, Maintenance And Servicing; Technical Specifications - WaterLogic 4 Firewall User Manual

Table of Contents

Advertisement

CLEANING, MAINTENANCE AND SERVICING

Weekly Cleaning
It is recommended that you clean your Waterlogic water dispenser at least once per week.
Please follow the cleaning procedure below:
Before starting, please turn off the power at the wall socket and remove the
power cord.
Please put on clean rubber gloves before commencing with the cleaning procedure.
Remove and empty the drip tray assembly.
Clean drip tray assembly and all machine surfaces with non-abrasive vending
machine cleaner/sanitizer.
Using an Anti Bacterial Wipe, thoroughly clean the water dispense buttons and
water dispense areas.
Reconnect mains power and check for correct operation.
If you should notice any damage or detect any leakage, turn off the water supply
and disconnect the power cord from the wall plug. If it is deemed safe then
contact your authorised service agent.
Your service agent will also be able to supply suitable cleaning/sanitising products for use
on your water dispenser as recommended by Waterlogic International Ltd.
Maintenance and servicing
To ensure that your Waterlogic water dispenser is always working to its optimum level, we
recommend that it is serviced by a trained technician every six months.
During these maintenance service visits, the filter(s) and UV lamp will be replaced. The
technician will also clean and sanitise the machine and ensure that it is operating correctly.
Models dispensing hot water will also be de-scaled as required (Hard water areas).
Please contact your authorised service agent to arrange your six monthly services.
Your authorised service agent is:
10
Waterlogic 4 Firewall User Manual- Issue 1, January 2011

TECHNICAL SPECIFICATIONS

DESCRIPTION
WL4 HCS
Machine Size
Base Cabinet Size
418mm(W) x 803.4mm(D) x 467.3mm(H)
Mini & BC Size
Machine Weight
35kg
Base Cabinet Weight
Power Supply
Heater
800W
16W
Fan
Compressor
114W
PCB
6W
Pump
12W
UV Lamp
11W
Others
27W
Unit Total
986W
Refrigeration Gas R134a
75g
Cold Tank Capacity
4.5 Litre
Hot Tank Capacity
1.2 Litre
CO2 Bottle (Max)
10kg
Water Connection
1/4" Hose 1/4" Hose 1/4" Hose 1/4" Hose 1/4" Hose
Minimum Water Pressure
0.15 (1.5) 0.15 (1.5) 0.15 (1.5)
Megapascal (Bar)
Maximum Water Pressure
0.35 (3.5) 0.35 (3.5) 0.35 (3.5)
Megapascal (Bar)
Recommended Water Pressure
0.30 (3.0) 0.30 (3.0) 0.30 (3.0)
Megapascal (Bar)
Extra Hot Water Temperature
93°C
Hot Water Temperature
87°C
Cold Water Temperature
6°C
Sparkling Water Temperature
6°C
Waterlogic 4 Firewall User Manual- Issue 1, January 2011
WL4 HC
WL4 CS
WL4 CA
417mm(W) x 439mm(D) x 470mm(H)
418mm(W) x 1238mm(D) x 470mm(H)
27kg
34kg
26kg
18kg
230 Volt / 50Hz
800W
N/A
N/A
16W
16W
16W
114W
114W
114W
6W
6W
6W
N/A
12W
N/A
11W
11W
11W
27W
27W
27W
974W
186W
174W
75g
75g
75g
4.5 Litre
4.5 Litre
4.5 Litre
1.2 Litre
N/A
N/A
N/A
10kg
N/A
0.15 (1.5)
0.15 (1.5)
0.35 (3.5)
0.35 (3.5)
0.30 (3.0)
0.30 (3.0)
93°C
N/A
N/A
87°C
N/A
N/A
6°C
6°C
6°C
N/A
6°C
N/A
WL4 C
26kg
N/A
16W
114W
6W
N/A
11W
18W
165W
75g
4.5 Litre
N/A
N/A
N/A
N/A
6°C
N/A