Step 3:
(a)
Mount devices in the most suitable locations (as suggested in Step 1).
(b)
Wire cabling directly into devices.
(c)
At this point install the 4.7K End of the Line (EOL) Resistor.
(Refer to Page 7).
The feature of this resistor is that when installed at the furthest point in the Zone,
tampering or interference with the wiring is not possible without setting off the alarm.
Note:
All joints connecting cables to EOL Resistors must be soldered and taped.
Step 4:
(a)
Install Master Control Panel and connect all cabling to panel.
(b)
A 240V GPO is required adjacent to the Master Control Panel position for the
Plug Pack.
Step 5:
Seal any unused or spare Zones with a 4.7K (EOL) end of line resistor.
Step 6:
Connect Battery, now Switch on Plug Pack supply.
Note:
Once the alarm system is powered up, control of the system is handed over,
and managed by the 8 Zone Keypad. All programming for the system is done
via the Keypad.
Step 7:
Upon power up the Zone 3 LED will be on, and the ON-LINE LED will also be on
indicating a system self test.
After the alarm panel has initiated this tests the panel will go into alarm if Zones 7 & 8
(24 hour Zones) are not sealed.
SUPA8 Quick Setup
3