Any key press
Turn SUPA8 OFF
Turn SUPA8 ON (only heard if exit beep is disabled)
Display of new data in programming mode
Wrong key or illegal action
*
Press
key
In Home Mode when a Home Beep Zone is triggered
Keypad lockout due to too many code entry attempts
During exit delay if Exit Beep is enabled
At end of exit delay if Exit Beep is disabled
During entry delay if Entry Beep is enabled

Keypad Lockout

If an incorrect code is entered 4 times then the keypad will be locked out
for 60 seconds. During this time the Zone lights will be on and the beeper
will sound continuously.

Keypad Entry Errors

When an error is made in entering digits, the keypad will emit a long beep
and resume idle mode. Just prior to the beep the Zone lights will display the
type of error that was detected:
Light ON
Error type
*
1
No matching code was found.
2
3
Keypad timeout has occurred.
Illegal key in current mode.
4
5
Illegal mode (either SUPA8 is ON or not in exit delay).
Action prevented by a programming option.
6
7
Address/Action is illegal for this code.