YASKAWA Varispeed G7 Instruction Manual page 184

General purpose inverter (advanced vector control)
Hide thumbs Also See for Varispeed G7:
Table of Contents

Advertisement

Name
Con-
stant
Display
Number
High-slip
Set in seconds the dwell time
braking stop
for the output frequency for
dwell time
FMIN (1.5 Hz) during V/f
N3-03
control.
HSB Dwell
Effective only during deceler-
Time
ation for high-slip braking.
High-slip
Set the OL time when the out-
braking OL
put frequency does not
time
N3-04
change for some reason dur-
ing deceleration for high-slip
HSB OL
braking.
Time
Speed Estimation: N4
User constants for speed estimation are shown in the following table.
Name
Con-
stant
Display
Number
Integral time
of speed esti-
Set the integral time of the
mator
N4-07
speed estimator for PI con-
trol.
SPD EST I
Time
Proportional
gain of speed
Set the proportional gain of
estimator
N4-08
the speed estimator for PI
control.
SPD EST P
GAIN
High-speed
proportional
Set the high-speed propor-
gain of speed
N4-10
tional gain of the speed esti-
estimator
mator for PI control.
OBS Gain H-
SPD
Speed estima-
Set the switching frequency
tor switching
of high-speed/low-speed
frequency
N4-11
operation for the speed esti-
Speed
mator.
Change F
Low-speed
Increase this setting if a
regeneration
higher power for low-speed
stability coef-
regeneration is required. If
N4-15
ficient 1
the setting is too large, the
torque reference monitor and
LowSpd Rgn
the actual torque accuracy
Coef1
may deteriorate.
Torque
adjustment
Set the torque adjustment
gain
N4-17
gain for low-speed power.
TRQ adjust
gain
Setting
Factory
Description
Range
Setting
0.0 to
10.0
30 to
1200
Setting
Factory
Description
Range
Setting
0.060
0.000
to
9.999
0.030
0 to
1000
0 to
1000.0
40 to
70 Hz
70
0.0 to
3.0
0.0 to
5.0
Control Methods
Change
Open
during
V/f
Loop
Opera-
V/f
with
Vec-
tion
PG
tor
1
1.0 s
No
A
A
No
40 s
No
A
A
No
Control Methods
Change
Open
during
V/f
Loop
Opera-
V/f
with
Vec-
tion
PG
tor
1
ms
No
No
No
No
ms
15
No
No
No
No
15.0
No
No
No
No
No
No
No
No
0.3
No
No
No
No
0.8
No
No
No
No
User Constant Tables
MEMO-
Open
BUS
Flux
Loop
Page
Regis-
Vec-
Vec-
ter
tor
tor
2
No
No
58AH
-
No
No
58BH
-
MEMO-
Open
BUS
Flux
Loop
Page
Regis-
Vec-
Vec-
ter
tor
tor
2
No
A
59AH
4-20
No
A
59BH
-
No
A
59DH
4-20
7-34
No
A
59EH
10-4
No
A
5A2H
7-34
No
A
5A4H
7-34
5-
71