Jog frequency
reference
d1-17
Jog
Reference
Note The unit is set in o1-03 (Frequency units of reference setting and monitor). The default for o1-03 is 0 (increments of 0.01 Hz).
* The setting range for open-loop vector 2 control is 0 to 66.0 (0 to 132.0 for PRG: 103 )
Reference Limits: d2
User constants for frequency reference limits are shown in the following table.
Con-
stant
Number
Frequency
reference
upper limit
d2-01
Ref Upper
Limit
Frequency
reference
lower limit
d2-02
Ref Lower
Limit
Master speed
reference
lower limit
d2-03
Ref1 Lower
Limit
-28
5
Name
Description
Display
The frequency reference
when multi-step speed refer-
ences 1, 2, and 4 are ON for
multi-function inputs.
The frequency reference
when multi-step speed refer-
ences 3 and 4 are ON for
multi-function inputs.
The frequency reference
when multi-step speed refer-
ences 1, 3, and 4 are ON for
multi-function inputs.
The frequency reference
when multi-step speed refer-
ences 2, 3, and 4 are ON for
multi-function inputs.
The frequency reference
when multi-step speed refer-
ences 1, 2, 3, and 4 are ON
for multi-function inputs.
The frequency reference
when the jog frequency refer-
ence selection, FJOG com-
mand, or RJOG command is
ON.
Name
Description
Display
Set the output frequency
upper limit as a percent, tak-
ing the max. output frequency
to be 100%.
Sets the output frequency
lower limit as a percentage of
the maximum output fre-
quency.
Set the master speed refer-
ence lower limit as a percent,
taking the max. output fre-
quency to be 100%.
Control Methods
Change
Setting
Factory
during
Range
Setting
Opera-
V/f
with
tion
0.00 Hz
Yes
A
0.00 Hz
Yes
A
0.00 Hz
Yes
A
0 to
400.00
*
0.00 Hz
Yes
A
0.00 Hz
Yes
A
6.00 Hz
Yes
Q
Control Methods
Change
Setting
Factory
during
Range
Setting
Opera-
V/f
with
tion
0.0 to
100.0%
No
A
110.0
0.0 to
0.0%
No
A
110.0
0.0 to
0.0%
No
A
110.0
MEMO-
Open
Open
BUS
V/f
Loop
Flux
Loop
Regis-
Vec-
Vec-
Vec-
ter
PG
tor
tor
tor
1
2
A
A
A
A
28DH
A
A
A
A
28EH
A
A
A
A
28FH
A
A
A
A
290H
A
A
A
A
291H
Q
Q
Q
Q
292H
MEMO-
Open
Open
BUS
V/f
Loop
Flux
Loop
Regis-
Vec-
Vec-
Vec-
ter
PG
tor
tor
tor
1
2
A
A
A
A
289H
A
A
A
A
28AH
A
A
A
A
293H
Page
-
-
-
-
-
4-6
6-5
6-84
Page
6-34
6-79
6-34
6-79
6-34
6-79