Motor 2 Setup: E4
User constants for motor 2 are shown in the following table.
Con-
stant
Number
Motor 2 rated
current
E4-01
Motor Rated
FLA
Motor 2 rated
slip
E4-02
Motor Rated
Slip
Motor 2 no-
load current
E4-03
No-Load
Current
Motor 2 num-
ber of poles
(number of
E4-04
poles)
Number of
Poles
Motor 2 line-
to-line resis-
tance
E4-05
Term Resis-
tance
Motor 2 leak
inductance
E4-06
Leak Induc-
tance
Motor 2 rated
capacity
E4-07
Mtr Rated
Power
* 1. The factory setting depends on the Inverter capacity. The value for a 200 V Class Inverter of 0.4 kW is given.
* 2. The setting range is from 10% to 200% of the Inverter rated output current. The value for a 200 V Class Inverter for 0.4 kW is given.
* 3. If a multi-function input is set for motor 2 (H1-
of 0.4 kW is given. The upper limit depends on the setting of E4-01.
* 4. The same capacity as that of the Inverter will be set if the constants are initialized.
-38
5
Name
Description
Display
Sets the motor rated current in
1 A units.
These set values will become
the reference values for motor
protection, torque limits and
torque control.
This constant is automatically
set during autotuning.
Sets the motor rated slip in
Hz units.
These set values will become
the reference values for slip
compensation.
This constant is automatically
set during autotuning.
Sets the motor no-load cur-
rent in 1 A units.
This constant is automatically
set during autotuning.
Sets the number of motor
poles.
This constant is automatically
set during autotuning.
Sets the motor phase-to-phase
resistance in Ω units.
This constant is automatically
set during autotuning.
Sets the voltage drop due to
motor leakage inductance as a
percentage of the motor rated
voltage.
This constant is automatically
set during autotuning.
Set the rated output of the
motor in units of 0.01 kW.
This constant is automatically
set during autotuning.
Change
Setting
Factory
during
Range
Setting
Opera-
tion
0.32
1.90 A
No
to 6.40
*1
*2
0.00 to
2.90 Hz
No
20.00
*1
0.00 to
1.20 A
No
1.89
*1
*3
2 to 48
4 poles
No
0.000
9.842
to
No
65.000
*1
0.0 to
18.2%
No
40.0
*1
0.00 to
0.40
No
650.00
*4
= 16), the setting range will depend upon the Inverter capacity. The value for a 200 V Class Inverter
Control Methods
MEMO-
Open
Open
BUS
V/f
Loop
Flux
Loop
Regis-
V/f
with
Vec-
Vec-
Vec-
PG
tor
tor
tor
1
2
A
A
A
A
A
321H
A
A
A
A
A
322H
A
A
A
A
A
323H
No
A
No
A
A
324H
A
A
A
A
A
325H
No
No
A
A
A
326H
A
A
A
A
A
327H
Page
ter
6-57
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents