Console CCE Series Table of Contents Model Decoder General Information Inspection Introduction Storage Unit Protection Pre-Installation Chassis Dimensions Installation Supply and Return Hoses Installation of Supply and Return Piping Condensate Piping Electrical Wiring Optional Wall Mounted Thermostat Start-Up Preparation System Checkout -407 onsole Unit Start-Up...
Page 2
C L I M A T E M A S T E R W A T E R - S O U R C E H E A T P U M P S C o n s o l e s R e v.
Notify the Keep both the chassis and cabinet covered with ClimateMaster Traffic Department within fifteen (15) the shipping carton until all plastering, painting, days of receipt of all damaged shipments.
NOTE: An Installation Checklist is provided in this man- Optional pressure-rated hose assemblies are available for ual. Complete this checklist after all installation proce- use with ClimateMaster CCE Units. Use the following dures are completed. A periodic maintenance checklist guidelines when installing supply and return hose provided in the Maintenance section outlines recom- assemblies.
When desired, the unit can be furnished with a 24-volt CAUTION: Use only copper conductors for field control circuit which is field-wired to a ClimateMaster- installed electrical wiring. Unit terminals are not supplied accessory remote thermostat.
DO NOT operate units without filters Safety Control Reset in place. DO NOT use equipment as a temporary All ClimateMaster heat pumps are furnished with high- heating or cooling source during construction. pressure, low-pressure and low-temperature cutouts to prevent the machine from operating at abnormal CONDENSATE PANS: Check condensate drain pans conditions of temperature or water flow.
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y C o n s o l e s R e v. : 0 8 / 1 3 / 1 0 Wiring Diagram Matrix All wiring diagrams can be located on the web at climatemaster.com Wire Diagram Model Refrigerant...
Page 20
C L I M A T E M A S T E R W A T E R - S O U R C E H E A T P U M P S C o n s o l e s R e v.
Page 21
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y C o n s o l e s R e v.
Page 22
C L I M A T E M A S T E R W A T E R - S O U R C E H E A T P U M P S C o n s o l e s R e v.
Page 23
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y C o n s o l e s R e v.
Page 24
C L I M A T E M A S T E R W A T E R - S O U R C E H E A T P U M P S C o n s o l e s R e v.
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y C o n s o l e s R e v.
Page 26
Check thermostat wiring at heat pump. Jumper Y and R for Thermostat wiring compressor operation in test mode. Unit Doesn't Operate in Set for cooling demand and check 24VAC on RV coil and at Reversing Valve C L I M A T E M A S T E R W A T E R - S O U R C E H E A T P U M P S Cooling CXM/DXM board.
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Location: ________________________ C o n s o l e s Model Number: ________________________ R e v.
97B0045N02 Oklahoma City, OK 73179 ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time for order may be changed Phone: 405-745-6000 *97B0045N02* without notice and may not be as described herein. Please contact ClimateMaster’s Customer Service Department at +1-405-745-6000 for specific ClimateMaster works continually to improve its products.