On-Line Preset; Mws Preset - Sharp UP-3500 Instruction Manual

Pos terminal
Hide thumbs Also See for UP-3500:
Table of Contents

Advertisement

I I I I I On-line preset
(1) Select the PGM2 mode and touch the [2 POS SETTING] to perform the programming.
(2) Touch the [9 SYSTEM] button to display the menu, and touch the [7 ONLINE PRESET] button to
program.
(3) Touch the required program item, and enter each parameter and touch the [ENTER] key.
Repeat this step (3) satisfactorily.
(4) To terminate the programming, touch the [EXIT] key.
Text
CHANNEL#
TERMINAL No.
CI SIGNAL
LINE FORM
BAUD RATE
START CODE
END CODE
TIME OUT
AT COMMAND OPEN
AT COMMAND CLOSE
I I I I I MWS preset
(1) Select the PGM2 mode and touch the [2 POS SETTING] to perform the programming.
(2) Touch the [9 SYSTEM] button to display the menu, and touch the [8 MWS PRESET] button to program.
(3) Touch the required program item, and enter each parameter and touch the [ENTER] key.
Repeat this step (3) satisfactorily.
(4) To terminate the programming, touch the [EXIT] key.
Text
MWS1 IP ADDR. 1
MWS1 IP ADDR. 2
MWS1 IP ADDR. 3
MWS1 T-NO.
MWS1 TIME OUT
MWS2 IP ADDR. 1
MWS2 IP ADDR. 2
MWS2 IP ADDR. 3
MWS2 T-NO.
MWS2 TIME OUT
G.W. ADDR. 1
G.W. ADDR. 2
G.W. ADDR. 3
G.W. ADDR. 4
194
(9 SYSTEM
7 ONLINE SETTING .......... PGM2)
Parameter
0 – 5 "0" means no RS-232 channel is assigned.
6 digits (0 to 999999 : 000001)
Sensing of the CI signal SENSING/NON
Half duplex/Full duplex SYSTEM HALF/FULL
Transmission data rate (Baud rate) 115200 bps 57600 bps
38400 bps 19200 bps 9600 bps 4800 bps 2400 bps
3 digits (0 to 127 : 002)
3 digits (0 to 127 : 013)
3 digits (1 to 255 (sec) : 007)
50 characters (null)
50 characters (null)
(9 SYSTEM
8 MWS PRESET .......... PGM2)
Parameter
3 digits (0 to 255 : 192)
3 digits (0 to 255 : 168)
3 digits (0 to 255)
3 digits (0 to 254)
3 digits (1 to 255 (sec) : 007)
3 digits (0 to 255 : 192)
3 digits (0 to 255 : 168)
3 digits (0 to 255)
3 digits (0 to 254)
3 digits (1 to 255 (sec) : 007)
3 digits (0 to 255 : 192)
3 digits (0 to 255 : 168)
3 digits (0 to 255)
3 digits (0 to 254)
Classification
Device assign
Terminal no.
Sensing of the CI signal
Transmission line form
Baud rate
Start code
End code
Time out time
At command with open store
At command with close store
Classification
IP address 1 (for MWS1)
IP address 2 (for MWS1)
IP address 3 (for MWS1)
MWS1 terminal no. (IP address)
Time out time (for MWS1)
IP address 1 (for MWS2)
IP address 2 (for MWS2)
IP address 3 (for MWS2)
MWS2 terminal no. (IP address)
Time out time
GATEWAY address
GATEWAY address
GATEWAY address
GATEWAY no. (IP address)
www.cashregisters.net

Advertisement

Table of Contents
loading

Table of Contents