Utility Output Command; Installer's Programming Commands [Q]+[8]+[Installer's Code]; At Home" Arming; Quick Arm" Command - DSC PC3OOO Installation Manual

Table of Contents

Advertisement

Group B access code, any access code, or no code at all.
When the proper keys are pressed the keypad sounder and
the programmable output are activated for 5 seconds.
Installer's Programming Commands
[Q]+[8]+[INSTALLER'S CODE]
The PC3000 is completely programmed from the keypad by
using commands in the [Q] [8] section. The commands are
described in detail in the programming section of this
manual.

"At Home" Arming

[Q]+[9]+[ACCESS CODE]
Entering [Q], [9] before the arming code, arms the panel
without any entry delay on the delay zones and bypasses
zones that are defined as "Home-Away". This command is
used for arming the system while at home. When the panel
is armed using [Q], [9], the "Armed" light will be on flashing
and the "Bypass" light will be on to indicate that the "Home-
Away" zones are bypassed. Once the panel is armed in this
mode, using [Q], [1] will remove the bypass from those
zones defined as "Home-Away" if they have NOT been
manually bypassed. The [Q], [1] command used here, only
removes the bypass from zones that have been
Automatically bypassed with the [Q], [9] command."

"Quick Arm" Command

[Q]+[0]
Entering [Q][0] is accepted as a valid arming code when the
"Quick Arm" feature is activated. Quick Arm may be used
as a convenience for regular users or when the sytem is to
be armed by individuals who are not authorized to disarm
the system. See instructions in the "[Q][6] User's Functions
Command" section for activating the "Quick Arm" feature.
This feature should not be enabled if the One Time Use
Code is enabled. The One Time Use Code must be used for
arming before it is erased.

Quick Exit

[Q]+[0] When Armed
Entering [Q] [0] when the system is fully armed will allow the
user 2 minutes to exit the premises through any delay zone
without altering the status of the system if the Quick Exit
feature is enabled. The Quick Exit feature can be enabled
by turning on light 6 in section [51]. After [Q] [0] is entered
into an armed system, one and only one delay zone may be
tripped. Any additional activity on any other active zone will
cause that zone to begin its alarm sequence.
[Q] [0] for Quick Exit on a partially armed system is not
supported.

Keypad Zones

There are three zones which can be activated from the
keypad. The alarm and restoral codes for keypad zones are
programmed using the [Q][8] command.
Pressing the [F] key for 2 seconds activates a Fire alarm.
The fire alarm sounds the siren/bell in a pulsed mode and is
annunciated as a memory condition.
Pressing the [A] key for 2 seconds activates an Auxiliary
keypad zone. If a reporting attempt is made to an alarm
receiver and it is successful the PC3000 will acknowledge
the transmission with a short series of beeps from the
keypad.
Pressing the [P] key for 2 seconds activates the Police (or
Panic) alarm. The panic alarm can be programmed for
audible or silent operation (see section [18] in
"Programming Guide").
There is no light annunciation from the keypad for the last
two keypad zones, however, the keypad buzzer beeps 3
times to confirm activation on any of the keypad zones. If
the keys are held down the buzzer continues to beep. The
panic alarm can be programmed for silent confirmation in
section [51] light 4.
See section [15] for alarm and restoral codes for all three
keypad zones.