Programmable Output Types; Circuit Output Types; System Output Types - Menvier Security TS2500 Installation & Programming Manual

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

TS2500 Installation Manual

Programmable Output Types

The TS2500 output types are broken down in to four
specific groups:
Circuit
Output types related to the status of detection
circuits 0001 to 8128.
System
Output types related to the status of the alarm
system in general.
User
Output types related to the user codes 001 to
199 being used.
Ward
Output types related to the status of wards A to
P.

Circuit Output Types

1
Mimic
Activates when the selected circuit is active,
deactivates when the selected circuit is healthy.
2
Alarm
Activates when the selected circuit causes an
alarm, deactivates when alarm is reset.
3
Tamper
Activates when the selected circuit is in tamper,
deactivates when tamper is reset.
4
Test Fail
Activates when the selected circuit is triggered
whilst on test, deactivates when the engineer
clears the test failures.
5
Omit
Activates when the selected circuit is omitted,
deactivates when the selected circuit is
reinstated.

System Output Types

00
Bell (SAB)
Activates when the control panel bell output is on,
deactivates when the control panel bell output is
off.
01
System Strobe
Activate when the control panel strobe output is
on, deactivates when the control panel strobe
output is off.
02
Switch 12 Volts
Activates when any ward is set, deactivates when
any ward goes into alarm or entry mode. This
output is normally used for latching detectors
03
Detector Reset
Active all the time to power latching detectors
(s mok e d e te ctor s, sho c k se nso rs et c.),
deactivates for 2 seconds when a code is entered
to set the first ward.
04
Walk Test
Activates when the walk test option is selected,
deactivates when the walk test is exited.
05
Alarm
Activates when any ward is in alarm, deactivates
when all ward alarms have been reset.
06
Panic Alarm (PA)
Activates when any PA alarm is detected,
deactivates when all PA alarms have been reset.
07
Fire Alarm
Activates when any fire alarm is detected,
deactivates when all fire alarms have been reset.
08
System Set
Activates when any ward is set, deactivates when
all wards are unset.
09
Code Accepted
Activates for the duration of the "Access Code
Time" after any valid passcode has been entered.
10
24hr Alarm
Activates when any 24Hr alarm is detected,
deactivates when all 24Hr alarms have been
reset.
11
2nd Alarm
Activates for the duration of the "2nd Alarm Time"
when any ward has a second detector causing an
alarm (alarm confirmation).
12
Courtesy Light
Activates for the duration of the "Courtesy Time"
when any ward is in entry or if any keypad is
operated.
13
Engineer on site
Activates when the engineer's code is entered,
deactivates when the engineer is logged off.
14
Circuits Omitted
Activates when any circuit is omitted , deactivates
when all circuits are reinstated.
15
Auxiliary Alarm
Activates when any ward auxiliary alarm is
activated, deactivates when all ward auxiliary
alarms are reset.
16
Always on
Active at all times.
17
Bell (SCB)
This is output type 00 inverted.
18
Auxiliary Fuse
Activates when the auxiliary fuse blows.
19
Auto-Setting
Activates for 1 minute prior to any ward being set
automatically.
20
Tamper Alarm
Activates when a tamper alarm is triggered,
deactivates when all tamper alarms have been
reset.
Engineer's Menu 1