Engineers Menu 3
Built In Tests
The TS2500 system has the following diagnostic routines:
9
Engineers menu 3
Built in tests
Panel version is
TS2500 - Ver 2.0
1
Voltage 13.60V
2
Current 1084mA
3
[ENT] to view :-
Cct resistance
[ENT] to test :-
4
C
digicom outputs
A
5
[ENT] to test :-
Panel outputs
6
[ENT] to test :-
Node outputs
7
[ENT] to CONFIRM
Network devices
8
[ENT] to test :-
Keypad display
9
[ENT] to view :-
Network devices
[ENT] to view :-
Network errors
[ENT] to do
False setting
[ENT] to test :-
digicom channels
Built In test Menu Flowchart
Software Version
When selecting the built in tests routine the software
version is displayed until you select one of the other
diagnostic routines.
Voltage
When this test option is selected the battery charging
voltage at the control panel is displayed, the accuracy
of this measurement is ± 0.2V.
Current Consumption
When this test option is selected the total current
consumption for the system is displayed, the accuracy
of this measurement is ± 50mA.
68
[3-9]
[
View Circuit Resistance
When this test routine is selected the resistance for each
detection circuit may be measured, the accuracy of
this measurement is ± 0.1 KOhms.
[ENT] to view :-
3
Cct resistance
Device type
TSLEC8
Circuit No.
0001 2K2
A
= Next circuit
C
= Previous circuit
View Circuit Resistance Flowchart
Test Digicom outputs
This test routine allows the engineer to test all eight
digicom outputs on the main control panel PCB.
[ENT] to test :-
4
Digicom outputs
Digi outputs on
1 * 3 * * * * *
1 8
-
Test Digicom Outputs Flowchart
Test Panel outputs
This test routine allows the engineer to test the four
control panel outputs.
[ENT] to test :-
5
Panel outputs
Panel outputs on
1 4
-
Test Panel Outputs Flowchart
TS2500 Installation Manual
[
Resistance
]
[
Outputs
*=off
to toggle outputs
]
[
Outputs
1 * 3 4
*=off
to toggle outputs
]