Item
Description
8
A, B, C, D preset
buttons
Beeper
Display
9
High Limit Reset Switch
10
Gas Control Valve
Switch
11
Drain Lever
12
Fill Lever
13
Pump Motor Reset
Switch
14
Rinse Hose Connector
15
Ignition Lock-out Light
16
Reset Switch
17
Ignition Module
18
Pilot Assembly
19
Locking Hook Handle
20
Lid Handle
Function
These buttons are used to save and recall preset cycle and alarm
times, saving operator time and minimizing error when changing
interval cycle times and alarm times. To save the current interval
and alarm times into one of the preset locations, press and hold the
A, B, C, or D preset button for 2 seconds and the controller will
double chirp to indicate the times have been saved. To recall any
preset time, press and quickly release the appropriate button and
the time values are loaded and displayed. These buttons are also
used to reconfigure the STIR OIL function.
A beeper sounds when the timer counts down to 0. Pressing the
START/STOP button stops the beeper and resets the timer causing
the display to return to the original starting time. At this point, time
can be changed using the TIME SELECT buttons or the preset
buttons. The beeper will also sound for 10 seconds if the alarm time
has elapsed during a timing cycle. When the STIR OIL function
begins the beeper will sound until the ALARM or START/STOP
button is pressed.
Used to display the time. It also displays the words "STIR" then
"OIL" in .5 second intervals until the ALARM or START/STOP
button is pressed.
If shortening inside the pot reaches an unsafe temperature, power
is automatically removed from the control panel and the gas system
shuts off. Pressing this switch returns power to the control panel
and resets the gas system.
ON – Allows gas to flow when the FILTER/OFF/FRY switch is set to
the FRY position and the thermostat calls for heat.
OFF – Prevents gas flow regardless of FILTER/OFF/FRY switch
and thermostat settings.
DRAIN OPEN – When placed in this position, the drain valve opens
and shortening drains into the vat. Also power is removed from the
control panel and gas system.
DRAIN CLOSED – When placed in this position, the drain valve is
closed to prevent shortening from draining into the pot. Also power
is restored to the control panel and gas system.
FILL THRU POT – When placed in this position, shortening will be
pumped from the vat to the pot if the rocker switch is in the FILTER
position.
FILL THRU HOSE – When placed in this position, shortening will be
pumped from the vat to the pot via a fill hose if the rocker switch is
in the FILTER position.
If the motor overheats while filtering, it will automatically shut off.
Wait 15 minutes to allow motor to cool before pressing this switch.
Used to connect the Rinse hose for cleaning and refilling the pot.
Illuminates when the Ignition Module locks out during ignition.
Used to reset the Ignition Module when it locks out during ignition.
Connects to the gas valve. Controls the pilot assembly and gas
valve.
Contains the pilot flame hood, ignition, and flame sense probes
Handle used to release the lid's locking hook.
Used to open and close the Lid Assembly.
14
Operation

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lgf-fc