BKI LGF-F Service Manual page 22

Gas pressure fryer
Table of Contents

Advertisement

Gas Pressure Fryer
STEP
ACTION
1
Press the FILTER/OFF/FRY
switch to FRY.
2
Press PROG on the keypad.
3
Input 1712 and ENTER.
4
Press ENTER.
5
Press TOGGLE/CLEAR until
the desired option is displayed.
6
Press ENTER.
7
Press TOGGLE/CLEAR until
the desired option is displayed.
8
Press ENTER.
9
Press TOGGLE/CLEAR until
the desired option is displayed.
10
Press ENTER.
11
Press TOGGLE/CLEAR and
input the number of fry cycles
you want to complete among
all product programs before
enabling filter lockout.
12
Press ENTER.
13
Press PROG to exit the
programming mode.
Table 1. System Programming Procedure
DISPLAY
PROGRAM CODE
PROGRAM SYSTEM
PROGRAM DEGREES
PROGRAM DEGREES
PROGRAM APL TYPE
PROGRAM APL TYPE
PROGRAM MELTCYCL
PROGRAM MELTCYCL
PROGRAM GLBLFLTR
PROGRAM GLBLFLTR
PROGRAM SYSTEM
20
COMMENTS
LOW
This command allows you to
°F
choose the temperature scale
option you want to use. The
display will show either show
°F or °C.
X refers to the temperature
X
scale you have chosen.
This command allows you to
GAS
choose the appliance type you
are using. The display may
show ELECTRIC, GAS OR
ALF.
X refers to the appliance type
X
you have chosen.
This command allows you to
YES
set the melt cycle option. This
is normally set to yes if you are
using solid shortening. The
display will show either YES or
NO.
X refers to the melt cycle
X
option chosen.
This command allows you to
0
specify the total number of fry
cycles to complete among all
product programs before a
message is displayed
reminding you to filter the
shortening (filter lockout).
X refers to the number of
X
program cycles you want to
complete among all product
programs before filtering the
shortening.
LOW
Operation

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lgf-fc

Table of Contents