RS-232C Adjustment Mode

70. POWER DELAY ON

(for 4 screens and 9 screens)
Function
This external control apparatus turns on power to multiple
displays with a time lag.
Transmit Data
DFH 80H 60H F2H 01H DATA00 CKS
DATA00 : 00H–FFH : time lag time (seconds)
* This command is valid when the screen division setting is 1
screen, 4 screens, or 9 screens.
* This command is premised on the system configuration of the
multiple displays being a multi-system. The master OSD
operation command is issued when the value of DATA is 01H
(1 second). Because this command is a one-way command,
there is no ACK.
71. POWER DELAY ON
(for 16 screens and 25 screens)
Function
The external control apparatus turns on power to multiple
displays with a time lag.
Transmit Data
Function
External control apparatus attaches a time lag to 10 or more
plasma monitors, and turns on a power supply.
Transmission Data
DFH 80H 60H F6H 01H DATA00 CKS
DATA00 : 01H mode 1
02H mode 2
ACK
7FH 60H 80H F6H 01H DATA00 CKS
DATA00 : 01H mode 1
02H mode 2
* This command is effective only when the screen division setting
is 16 screens or 25 screens.
82
72. ORBITER SET
Function
This sets the picture shift function (*1).
It switches between PC Menu, Long Life, and Picture Shift.
Transmit Data
DFH 80H 60H 1EH 04H DATA00–DATA03 CKS
DATA00 : mode
DATA01 : quantity of horizontal shift
DATA02 : quantity of vertical shift
DATA03 : shifting interval
ACK
7FH 60H 80H 1EH 01H DATA00 CKS
DATA00 : mode
* DATA01–03
When auto1, 2 is set : setting 01H
When manual is set : setting is valid

73. OSM ANGLE

Function
It selects OSM vertical and horizontal displays.
Transmit Data
DFH 80H 60H 60H 01H DATA00 CKS
DATA00 01H : horizontal display
02H : vertical display
ACK
7FH 60H 80H 60H 01H DATA00 CKS
DATA00 01H : horizontal display
02H : vertical display
00H : off
01H : auto1
02H : auto2
03H : manual
1 dot
: 01H
: –
20 dots
: 14H
1 line
: 01H
: –
0 lines
: 14H
1–5 minutes : 01H–05H
00H : off
01H : auto1
02H : auto2
03H : manual