Diagnosis For Shutdown And Power-Down By Led - Pioneer PRO-1000HDI Service Manual

Hide thumbs Also See for PRO-1000HDI:
Table of Contents

Advertisement

5

8.1.2 DIAGNOSIS FOR SHUTDOWN AND POWER-DOWN BY LED

This unit has self-diagnosis functions against abnormalities in the internal circuits and other operational abnormalities, and if any abnormality is
detected, the STANDBY/ON indicator (LED) blinks to alert you of it.
How the indicator blinks and possible failure points and power-down points are explained below:
Shutdown
• Operations : When a microcomputer detected abnormality, it turns the power supply OFF.
• LED display : Blinking in green
Example: How the LED blinks when DIGITAL-IIC communications fail
Green LED lights
for 200 msec.
Number of
blinking
1
Panel Microcomputer failure
2
DIGITAL-IIC communication failure
3
Condensation
4
Temperature abnormality
5
FAN abnormality
6
Module microcomputer failure
7
Wide microcomputer failure
8
RGB-IIC communication failure
9
Audio failure
Power-down
• Operations : In an emergency, the protection circuits are activated, and the power is turned off.
• LED display : Blinking in red
Note: If more than two protection circuits are activated at almost the same time, the LED indicates this by its
blinking-pattern.
Example: How the LED blinks for the first power-down (Y-DC/DC CONVERTER) and the second power-down (Y DRIVE)
1st power-down information
Red LED lights
for 200 msec.
Number of
Failure Point
blinks
1
Y-DRIVE
2
Y-DC/DC CONVERTER
3
X-DC/DC CONVERTER
4
X-DRIVE
5
Power supply
6
Address junction
7
Address resonance
8
DIGITAL-DC/DC CONVERTER
5
6
Extinguished
Green LED lights
for 100 msec
Extinguished
for 3 sec
Reason
How to release shutdown
If the Power key on the remote control unit is pressed, the shutdown
status is released, and the unit will be turned on. (It is not necessary
to press the MAIN POWER button to turn off the unit.)
Extinguished
Red LED lights
for 100 msec
for 200 msec.
How to release power-down
Set the MAIN POWER button to OFF, and wait for about 30 seconds until
the LED for PD (power-down) in the power-supply module is extinguished.
Wait another 5 seconds, then recover the unit by setting the MAIN POWER
button to ON.
Note: After power-down is released, the unit restarts and goes in to Standby
mode.
6
7
for 200 msec.
Extinguished
for 1 sec
Extinguished
for 3 sec
PRO-1000HDI
7
8
A
B
C
D
2nd power-down
information
Red LED lights
for 200 msec.
E
F
155