Plug And Play; Osm Select - Pioneer PDP-61MXE1 Technical Manual

Pioneer 61-inch v ac type plasma display panel
Hide thumbs Also See for PDP-61MXE1:
Table of Contents

Advertisement

RS-232C Adjustment Mode

57. PLUG and PLAY

Function
The external control apparatus switches the EDID setting
of the plasma display.
Transmit Data
DFH 80H 60H 8EH 01H DATA00 CKS
DATA00 01H : PC
02H : STB/DVD (HDCP signal)
ACK
The plasma display returns the following ACK.
7FH 60H 80H 8EH 01H DATA00 CKS
DATA00 01H : PC
02H : STB/DVD (HDCP signal)
58. BLACK LEVEL SELECT
Function
The external control apparatus switches the signal level
setting of the plasma display.
Transmit Data
DFH 80H 60H 8FH 01H DATA00 CKS
DATA00 01H : low
02H : high
ACK
The plasma display returns the following ACK.
7FH 60H 80H 8FH 01H DATA00 CKS
DATA00 01H : low
02H : high
59. OSM CONTRAST SELECT
Function
The external control apparatus switches the OSM contrast
level setting of the plasma display.
Transmit Data
DFH 80H 60H 37H 01H DATA00 CKS
DATA00 01H : normal
02H : low
ACK
DFH 80H 60H 37H 01H DATA00 CKS
DATA00 01H : normal
02H : low
78

60. OSM Select

Function
The external control apparatus turns the screen display
(OSD) of the display on and off.
Transmit Data
DFH 80H 60H 58H 01H DATA00 CKS
DATA00 01H : OSD ON
02H : OSD OFF
ACK
DFH 80H 60H 58H 01H DATA00 CKS
DATA00 01H : OSD ON
02H : OSD OFF
It operates as shown on the following table.
Coordinates/displays
Operation
menu items
When OSD
is on
When operating with
Yes
a remote control
When operated
No
by PC control
61. INVERSE Set
Function
The external control apparatus sets INVERSE, WHITE of
the plasma display.
Transmit Data
DFH 80H 60H C7H 03H DATA00 DATA01 DATA02 CKS
DATA00 : INVERSE (reverse)/WHITE
DATA01 : WORKING TIME
(display setting)
DATA02 : WAITING TIME (interval)
ACK
3FH 60H 80H C7H 00H CKS
* Display setting, waiting time can be set in 3-minute units.
Example: 03H = 9 minutes, 1EH = 1 hour, 30 minutes
OSD display
Displays sound volume,
input, and screen size
When OSD
When OSD
When OSD
is off
is on
is off
Yes
Yes
No
No
Yes
No
00H : no change
01H : on (INVERSE)
02H : off
03H : white
00H : on
01H : 03M (minutes)
02H : 06M (minutes)
:
FFH : 12H (hours) 45M (minutes)
01H : 03M (minutes)
02H : 06M (minutes)
:
FFH : 12H (hours) 45M (minutes)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdp-614mx

Table of Contents