RS-232C Adjustment Mode
27. PHASE Gain Data
Function
The external control apparatus changes the PHASE Gain
Data (phase) of the display.
Transmit Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : PHASE Gain Flag
DATA02 : PHASE Gain
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : PHASE Gain Flag
28. CLOCK Gain Data
Function
The external control apparatus changes the CLOCK Gain
Data (frequency ratio) of the display.
Transmit Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : CLOCK Gain Flag
DATA02 : CLOCK Gain
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : CLOCK Gain Flag
70
03H
03H
00H : 0
:
40H : +64
03H
03H
03H
04H
C0H : -64
:
FFH : -01
00H : 0
01H : +01
:
40H : +64
03H
04H
29. OSM ADJ. POSITION Data
Function
The external control apparatus switches the Menu Position
of the display.
Transmit Data
7FH 60H 80H 1AH 02H DATA00 DATA01 CKS
DATA00 : OSM ADJ. Gain Flag 02H
DATA01 01H : 1 (upper left)
02H : 2 (upper center)
03H : 3 (upper right)
04H : 4 (lower left)
05H : 5 (lower center)
06H : 6 (lower right)
ACK
7FH 60H 80H 1AH 01H DATA00 CKS
DATA00 : OSM ADJ. Gain Flag 02H
30. POWER MGT Select
Function
The external control apparatus turns POWER MGT of the
display on and off.
Transmit Data
DFH 80H 60H 1AH 02H DATA00 DATA01 CKS
DATA00 : POWER MGT Select 03H
DATA01 01H : on
02H : off
ACK
DFH 80H 60H 1AH 02H DATA00 DATA01 CKS
DATA00 : POWER MGT Select 03H
DATA01 01H : on
02H : off
31. SIDE MASK Set
Function
The external control apparatus sets the SIDE MASK level
of the display.
Transmit Data
DFH 80H 60H C6H 01H DATA00 CKS
DATA00 : SIDE MASK
ACK
DFH 80H 60H C6H 01H DATA00 CKS
DATA00 : SIDE MASK
00H : 0
:
0FH : 15
00H : 0
:
0FH : 15