Hanging On The Wall - Pioneer PDP-61MXE1 Technical Manual

Pioneer 61-inch v ac type plasma display panel
Hide thumbs Also See for PDP-61MXE1:
Table of Contents

Advertisement

Special Instruction (Hanging on the wall)

2.4.2 Hanging on the wall

Carefully read the following before attempting to hang the unit on a wall, and observe the various limitations specified
below. Be sure to mount the unit so that twisting, bending, or any other deformation does not exceed 4 mm.
Ventilation Requirements for enclosure mounting
To allow heat to disperse, leave space between surrounding objects as shown on the diagram below when installing.
Operating temperature restrictions
✩ Standard single-unit installation
Distance from wall (A)
50 mm or more
✩ Requirements when used with PDP-S29-LR speaker system
Requirements are the same as those for standard single-unit installation.
However, dimensions refer to the distance between the speaker and the wall
Methods of Securing: Basic methods of securing are shown below. Avoid blocking or covering areas aside from those
indicated by
of the fittings, and the number of fixing bolts is correct. (Also refer to 2.4.1 "Mounting to fittings
(pg. 21)".)
Note
Heated air is drawn off from the interior of the unit by fans. Before installation, consider the heat resistance of the wall
or other surfaces behind the unit. Exhaust temperatures can be 30 °C higher than the outside temperature.
Note
For wall-mounting, do not bundle the cables in a way that will obstruct ventilation.
22
Wall
D
B
50 mm or more
50 mm or more
. Before attaching the unit to fittings, double-check that the thickness and height
D
C
D
50 mm or more
Wall
A
Ambient temperature
0 to 40°C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdp-614mx

Table of Contents