UNIVERGE SV8100
No internal Dial Tone to any Multiline Terminal or SLT
Turn system Off. Disconnect all connectors
and remove all blades except CD-CP00-US
and the first installed CD-8DLCA in the
controlling chassis associated with the
programming station.
Dial Tone
Build system, one blade
at a time until problem
reappears. Replace
defective blade.
Yes
1. If problem not solved, perform First Initialization
and test. If trouble persists go to step 2.
2. Replace CD-CP00-US and test system
using default program.
System Maintenance Manual
A1
Are LEDs on front of
chassis panel lit on
CD-CP00-US or any
other blade?
Yes
Turn system On.
Dial Tone on Multiline
Terminal on 1st
CD-8DLCA?
No Dial Tone
Reset CD-8DLCA. If trouble
persists, replace CD-8DLCA.
Dial tone?
No
No
Bad
Correct AC Power
Problem.
Bad
Replace
Fuse(s).
Replace Corresponding
Power Supply.
Yes
Done.
Remove all blades but
one CD-8DLCA, and
retest.
Build system
Yes
one blade at a
time and
replace bad
blade(s).
Issue 1.0
Check AC Input
Power.
AC Power?
Good
MPS7101
Fuses F1
and F2
good?
Good
Problem
Solved?
No
Problem
Solved?
No
Replace chassis.
2 - 5