Multiline Terminal Ringing D2 - NEC Univerge SV8100 System Maintenance Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Go to Flowchart C1.
Check to see if station is
call forwarded or in DID.
Yes
Station in
Call Forward
or DID?
Cancel
feature.
Yes
Send terminal
in for repair.
System Maintenance Manual
Multiline Terminal Ringing Problems
Intermittent
Problem?
Check to see if problem occurs on CO or
internal calls (including station-to-station
or transferred calls).
Internal
Problem?
Check and adjust
No
volume control, and
test again.
Problem
Solved?
Reset/replace station,
then reset or replace
CD-8DLCA.
Problem
Solved?
Reset/replace station,
then reset or replace
CD-8DLCA.
No
Problem
Solved?
D2
Consistent
CO
Check PRG 15-07.
Both
Yes
Done.
No
Yes
Done.
No
1. Perform Second Initialization, and test.
2. Perform First Initialization, and test.
3. Replace CD-CP00-US,
and test
Yes
Wrong
Program
Assignment?
again.
No
Check PRG 22-04
for ring assignment.
Yes
Wrong
Program
Assignment?
again.
No
Issue 1.0
2 - 13