Machine foundation

The machines are designed to be securely bolted
to a concrete pad. A template showing the size of
the pad and positioning of the bolts is delivered
with each machine.
For installation on an existing concrete floor, the
floor must be at least 8" thick and of good quality.
If the floor does not meet these requirements,
then a 6-8" high concrete pad should be made. A
prefabricated steel base is available for mounting
machines without pouring a pad.
Follow the instructions below when making a
concrete foundation:
1. Decide where to place the machine and
Fig.
consider maintenance requirements, i.e.
determine a suitable distance from the rear of
2
the pad to the wall, and the distance from the
pad to the nearest side wall. The distance
should be at least 16 and 12 inches,
respectively. Leave 3/4'' between washers.
2. Break up the floor to a minimum depth of 3
Fig.
inches, making sure that the sides of the hole
3
slope away - the bottom of the hole should be
5 inches longer than the upper length.
3. Wet the hole well. Brush the bottom and sides
with cement grout.
4. Prepare a casing and fill with 3.000 PSI
concrete to form pad. Make sure the
foundation is level.
5. Use the template to position the bolts
Fig.
correctly. Bolts are to extend 1 1/2" above the
4
concrete.
NOTE: A prefabricated steel frame, designed
to be placed in the concrete instead of the
individual mounting bolts, is available.
W75
W105
mm
inches
mm
A 364 14 11/32
481
B 593 23 11/32
710
C 648
25 1/2
760
D 100
4
100
E 530
20 7/8
530
G 700 27 9/16
700
H 643 25 5/16
715,6
I
-
-
-
K
-
-
-
W125
inches
mm
inches
18 15/16 508
20
27 15/16 910
35 13/16 960
29 15/16 1031
40 9/16 1078 42 7/16
4
142
5 9/16
20 7/8
600
23 5/8
27 9/16
800
31 1/2
28 3/16
786
30 15/16 922
-
991
39
-
281
11
Installation
2
3
4
W185
mm
inches
600
23 2/3
37 3/4
142
5 9/16
700 27 9/16
880
34 2/3
B = machine outline to edge of front panel
36 1/8
C, G = minimum foundation for one machine
1090 42 7/8
236
9 7/16
7
0271
1677
1132