Safety Instructions Safety Instructions • English Инструкция по технике безопасности • Русский WARNING: This symbol, , when used on the product, is intended to ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан alert the user of the presence of uninsulated dangerous voltage within the на...
Page 4
Conventions Used in this Guide Notifications The following notifications are used in this guide: Potential risk of severe injury or death. WARNING: AVERTISSEMENT : Risque potentiel de blessure grave ou de mort. ATTENTION: • Risk of property damage. • Risque de dommages matériels. NOTE: A note draws attention to important information.
............ 1 ... 21 About this Guide ..........1 Installing the XTP System Configuration Software ............21 About the XTP T HWP 101 ......... 1 Using the XTP System Configuration Key Features ............2 Software ............22 Connections ..........22 Installation ............
Page 6
XTP T HWP 101 Wallplate Transmitter • Contents...
XTP matrix switcher (see on page 13). To configure and control the XTP T HWP 101, connect a host device, such as a computer, to the USB Config port and enter Simple Instruction Set (SIS) commands (see Configuration and Control...
Figure 1 shows a typical point-to-point application of the XTP T HWP 101. Shielded Twisted Pair Cable t r o t r o Extron XTP T HWP 101 D IO D IF S /P XTP Transmitter HDMI D IO -2 32...
Page 9
Remote power capability — To simplify integration, the XTP T HWP 101 can be powered by an XTP CrossPoint Matrix Switcher or XTP Power Injector. Multiple embedded audio formats — Compatible with a broad range of multi-channel audio signals, providing reliable operation with HDMI sources.
• Making Connections Installation Overview The XTP T HWP 101 can be installed into the provided mud ring or a UL Listed metal electrical junction box. NOTE: If using a junction box, use a metal one only. Prepare the mounting surface.
Rear Panel Connectors Route and connect cables to the rear panel connectors (see on page 8). Mount the XTP T HWP 101 to the mud ring or metal junction box (see Mounting the XTP T HWP 101 on page 9).
NOTE: The backing clip can be installed as shown in Figure A or Figure B (see figure 3). Use a cross-head (Phillips) screwdriver to fasten the screws and backing clips in place. XTP T HWP 101 Wallplate Transmitter • Installation...
être réduit jusqu’à ce que le câble sorte de la cosse de câble. Le blindage tressé et le blindage en aluminium devraient être connectés à la masse d’un équipement à l’autre bout du câble. XTP T HWP 101 Wallplate Transmitter • Installation...
Rear Panel Connectors XTP output connector — Connect a twisted pair cable to the RJ-45 connector labeled “XTP OUT” on the XTP T HWP 101 and the XTP input port on another XTP TP Cable Termination and Recommendations device to pass all signals (see page 11).
Figure 7. Installing the XTP T HWP 101 in a Metal Junction Box Align the mounting screws on the XTP T HWP 101 with the available holes on the mud ring (see figure 6, ) or metal junction box (see figure 7,...
NOTES: • The maximum HDMI cable length is 15 feet. • Use an Extron HDMI LockIt Lacing Bracket to secure the HDMI connector to the device (see HDMI Connection on page 11). XTP T HWP 101 Wallplate Transmitter • Installation...
Orange Green Orange White-green White-orange White-green Blue Blue Blue White-blue White-blue White-blue Orange Green Green White-brown White-brown White-brown Brown Brown Insert Twisted Pair Wires Brown RJ-45 Connector Figure 10. TP Cable Termination XTP T HWP 101 Wallplate Transmitter • Installation...
Supported cables The XTP T HWP 101 is compatible with shielded twisted pair (F/UTP, SF/UTP, and S/FTP) cable. ATTENTION: • Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201 cable to link the XTP products. • N’utilisez pas le câble AV Skew-Free UTP version améliorée UTP23SF d’Extron ou le câble STP201 pour relier les produits XTP.
Connector Tie Wrap SECTION A–A 3/16” (5 mm) Max. Smooth Ridges Power Supply Output Cord Figure 11. Power Wiring The XTP T HWP 101 can be connected to a local power supply. XTP T HWP 101 Wallplate Transmitter • Installation...
Page 20
La longueur idéale est de 5 mm (3/16 inch). TIP: Do not tin the stripped power supply leads. Tinned wires are not as secure in the captive screw connectors and could be pulled out. XTP T HWP 101 Wallplate Transmitter • Installation...
Remote power The XTP T HWP 101 can be powered remotely through an XTP Power Injector or through an XTP matrix switcher. ATTENTION: XTP remote power is intended for indoor use only. No part of the network that uses XTP remote power should be routed outdoors.
Operation This section contains information for front panel operation and configuration of the XTP T HWP 101. Topics in this section include: • Front Panel Features • Reset Modes After all transmitters, all receivers, and their connected devices are powered up, the system is fully operational.
1 reset by NOT operate the firmware mistake, cycle power to the version that results from this device to return the firmware mode reset. version running prior to the reset. XTP T HWP 101 Wallplate Transmitter • Operation...
Error Responses When the XTP T HWP 101 receives an SIS command and determines that it is valid, it performs the command and sends the corresponding response to the host device. If the command is determined invalid or contains invalid parameters, the transmitter returns an error response to the host.
= Carriage return with no line feed = Pipe (can be used interchangeably with the character). = Space • = Escape key = Can be used interchangeably with the character. XTP T HWP 101 Wallplate Transmitter • SIS Configuration and Control...
= enable (default) = Video signal status = video or TMDS not detected = video or TMDS detected = HDCP status = No source = HDCP-compliant source = Non-HDCP compliant source XTP T HWP 101 Wallplate Transmitter • SIS Configuration and Control...
Configuration Software This section contains installation and configuration procedures for the XTP System Configuration Software for configuring and controlling the XTP T HWP 101. It can also be controlled with SIS commands (see SIS Configuration and Control on page 18). Topics in...
Using the XTP System Configuration Software The XTP T HWP 101 can be controlled directly from the rear panel Config port or remotely from an XTP matrix switcher. Connections The XTP System Configuration Software opens to the Connections screen. This screen...
To access this menu, click the Tools menu. Tools Figure 19. Tools Menu NOTE: The options are not Backup and Restore Software Preference available when directly connected to the XTP T HWP 101. XTP T HWP 101 Wallplate Transmitter • XTP System Configuration Software...
Select file from computer connected host device. The Browse dialog box opens. Select the desired firmware file and click the button. Open Click the button after the firmware finishes updating. Close XTP T HWP 101 Wallplate Transmitter • XTP System Configuration Software...
Page 31
This option opens the XTP System Configuration Software help file in a Web browser. From the menu, select Help Help Extron Website This option opens the Extron website in a Web browser. From the menu, select Help Extron Website XTP T HWP 101 Wallplate Transmitter • XTP System Configuration Software...
Factory Reset settings except for firmware. NOTE: This is the same as the SIS command (see the System reset ZXXX command on page 20). XTP T HWP 101 Wallplate Transmitter • XTP System Configuration Software...
Page 33
HDCP — Displays the HDCP status of the input. Current EDID Information section EDID — Displays the current resolution and refresh rate. Audio Information section This section does not apply to the XTP T HWP 101. XTP T HWP 101 Wallplate Transmitter • XTP System Configuration Software...
Page 34
Favorites, Connected Outputs, or Available EDID panel ( Below the list of inputs on the right side of the screen, click the button Assign to All XTP T HWP 101 Wallplate Transmitter • XTP System Configuration Software...
Page 35
Common tab appears, listing the EDID settings common among the selected outputs. Timings Select the desired common EDID setting. The EDID will be shown in the Available EDID panel. XTP T HWP 101 Wallplate Transmitter • XTP System Configuration Software...
• Mounting Template Updating Firmware with Firmware Loader To upload and update firmware for the XTP T HWP 101, download the new firmware to a connected computer and upload the firmware with the Firmware Loader utility. Downloading Extron Firmware Loader Figure 27.
Once Firmware Loader has been downloaded, run the .exe file from the location where the file was saved. The installation wizard window opens. Follow the instructions on the Installation Wizard screens to install Firmware Loader on the computer. XTP T HWP 101 Wallplate Transmitter • Reference Information...
The file can be downloaded from the same page as the firmware. Click the link to the right of the desired device. Download Submit any required information to start the download. Note where the file is saved. XTP T HWP 101 Wallplate Transmitter • Reference Information...
Click the button to start the upload process. Begin Close Firmware Loader when the field shows , the Remaining Time 00.00.00 column is , and the field is Progress 100% Status completed XTP T HWP 101 Wallplate Transmitter • Reference Information...
CUT-OUT AREA FOR WALL MOUNT Top Panel Figure 31. Mounting Template for 1-gang Mud Rings (Not to Full Scale) Please measure the printed template before cutting. NOTE: Measure the template before cutting. XTP T HWP 101 Wallplate Transmitter • Reference Information...
Page 41
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.
Need help?
Do you have a question about the XTP T HWP 101 and is the answer not in the manual?
Questions and answers