Loading New Firmware - Topcon HiPer Pro Operator's Manual

Receivers
Table of Contents

Advertisement

Operation

Loading New Firmware

Base and Rover receivers must be loaded with the same firmware
version. Use the latest firmware version, available for download from
the TPS website, to ensure your receiver has the most recent updates.
NOTICE
NOTICE
The HiPer Pro receiver should be loaded with firmware
version 2.4 or newer.
CAUTION
CAUTION
Do not use firmware versions 2.3p2 or older.
The receiver board and power board must be loaded with firmware
from the same package. The Bluetooth module's firmware is
independent of the receiver card and power board, and has a different
firmware package.
The receiver uses FLoader, a Windows®-based utility, to load
firmware onto the receiver and power boards. You can download
FLoader to your computer from the TPS website. For more
information, refer to the FLoader User's Manual, also available on
the TPS website.
1. Download and install FLoader, if applicable.
2. Download the new firmware package to your computer.
3. Connect your receiver and computer. See "Connecting the
Receiver and a Computer" on page 2-10 for this procedure.
4. Activate FLoader (Figure 4-14 on page 4-23).
5. On the Connection tab, select the COM port on your computer
that connects with your receiver and select it's speed (usually
115200) (Figure 4-14 on page 4-23).
4-22