Allen-Bradley 1770-M10 Assembly And Installation Manual page 42

Mass storage systems
Table of Contents

Advertisement

Appendix A
Care of Your Mass Storage System
A 2
humidity and corrosive vapors
Maximum Shock Without Incurring Physical Damage
Operating: 3g
Non-operating: 35g
Shock levels beyond this specification could result in loss of oxide media, head
misalignment, and/or permanent loss of all recorded data.
Maximum Vibration Without Incurring Soft Errors
Operating:
Series A Systems
2 to 22 Hz
0.010 inch double amplitude
22 to 500 Hz
1.0g
Maximum Vibration Without Incurring Physical Damage
Non-operating:
Series A Systems
2 to 22 Hz
0.040 inch double amplitude
22 to 500 Hz
1.0g
We test vibration two ways:
Operating: While operating, the product vibrates for a minimum of one
hour each at the X,Y, and Z axes at a rate of 15 minutes per sweep cycle over
a frequency range of 5 to 2000Hz.
Non-operating: With no power applied, the product vibrates for a minimum
of one hour each at the X,Y, and Z axes at a rate of 15 minutes per sweep
cycle over a frequency range of 5 to 2000Hz.
Dust
The Winchester disk drive of your mass storage system contains its own air
filtration system. The system permits circulation of internal air and equalization
Series B Systems
5 to 12 Hz
0.010 inch double amplitude
12 to 250 Hz
1.0g
Series B Systems
5 to 36 Hz
0.050 inch double amplitude
36 to 250 Hz
3.0g